Specifications - Desa CLD3924PTC Owner's Operation And Instruction Manual

Desa cld3924ptc; cld3924ntc gas log heater, 24" thermostatically-controlled models
Table of Contents

Advertisement

OPTIONAL POSITIONING OF THERMOSTAT
4. Mounting clip must be a minimum of 3"
from bottom of fireplace to prevent crimp-
ing of capillary. Once you have decided
on a location, clean area thoroughly.
Remove paper backing from adhesive on
back of mounting clip. Press clip into new
location so thermostat sensing bulb will
be positioned vertically with capillary at
bottom (see Figure 32). Slide thermostat
sensing bulb into clip.
IMPORTANT: Do not crimp capillary.
Thermostat
Sensing Bulb
Adhesive-
backed
Mounting Clip
Figure 31 - Installing Thermostat Sensing
Bulb behind Glass Doors
Model CLD3924PTC
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Pressure Manifold: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 14" W.C., Minimum* 11" W.C.
• Shipping Weight:
* For input adjustment
120890-01D
SENSING BULB
Glass Doors

SPEcIFIcATIONS

27 lbs.
www.desatech.com
Continued
Thermostat
Sensing Bulb
Capillary
Figure 32 - Positioning Thermostat
Sensing Bulb in Vertical Position with
Model CLD3924NTC
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas : Natural Gas
• Ignition: Piezo
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
• Shipping Weight:
* For input adjustment
Adhesive-
backed
Mounting Clip
Do Not Crimp
Capillary
Capillary at Bottom
29 lbs.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cld3924ntc

Table of Contents