Step 1
Cut the tube square and remove burrs and sharp edges. Ensure that the
outside diameter is free from score marks. For soft or thin walled plastic
tubing we recommend the use of a tube insert.
Step 2
Push the tube into the fitting and up to the tube stop
Pull on the tube to check that it is secure. Test the system before use.
Step 3
Sanitize the System (Recommended)
Sanitizing is recommended immediately after installation of the Reverse Osmosis system. It's also recom-
mended after servicing inner parts. It is important that the person installing or servicing the system have clean
hands while handling inner parts of the system.
1. Turn off the water supply to the RO system and close the ball valve on the storage tank.
2. Open the RO faucet.
3. Use an eyedropper (not included) and common household bleach (5.25%).
4. Add 3 ml (1 teaspoon) of bleach into open end of 3/8 tube connected to tank. Handle bleach according to
bleach manufacturer's recommendations.
5. Connect tubing back to tank ball valve.
6. Sanitizing the system will be completed during the Flush System and Check Operation steps on the follow-
ing page.
Note: The bleach must be removed from the system before drinking the water. See Flush System
instructions on the next page.
With all components in place, complete final tubing
connections using these guidelines:
 Tubing should follow contour of the cabinets
 Cut tubing to desired length using square cuts and
proper cutting device
 Make no sharp bends
 Keep tubing from the post-filter to the faucet as
short as practical for good flow.
 Leave enough tubing that the system can easily be
pulled out from the cabinet for easy filter changes.

Installing Tubing Into Fittings

Sanitize System

Installing Tubing Connections

Procedure (Standard Faucet)
Follow the directions on the labels installed on the
tube fittings.
1. Connect 3/8" tubing to faucet.
2. Connect ¼" tubing to drain saddle.
3. Connect 3/8" tubing storage tank.
4. Connect ¼" tubing to inlet water supply valve.
(For air gap models connect 1/4" tubing to faucet
and 3/8" tubing from faucet to drain saddle)
5. Check all connections to be sure they are secure.
6. Turn on feed water valve and check for leaks.