Recirculation Mode - AEG X91384MIO User Manual

Table of Contents

Advertisement

This cooker hood can be used to recirculate or extract contamina-
ted air.

Recirculation Mode

The cooker hood is supplied specified for use in the recirculation
mode with the charcoal filter fitted.
The contaminated air is cleaned by passing through the filters and
than back into the kitchen.
The activated charcoal filter absorbs odours arising from cooking. In
use it will slowly become saturated in grease and less effective. The
filter normally requires changing after at least every three months
or more frequently if the hood is used for more than three hours
per day.
• Insert the Connector extensions 14.1 into the side of
the Connector 15.
• Insert the Connector 15 into the Support bracket 7.3
and fix it with the screws.
• Fasten the Support bracket 7.3, fixing it to the upper
part with the Screws.
• Make sure that the Connector extensions outlet 14.1
is in correspondence with the Chimney openings both
horizontally and vertically.
• Join the Connector 15 to the Hood canopy outlet us-ing
a rigid or flexible pipe ø¸150 mm, selection of which is
at the discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has
been fitted.
Extraction (Ducted)
The cooker hood is more effective when installed in the extraction
mode (ducted to the outside).
Venting kits may be purchased through your retailer or DIY store,
and must be evacuated through an outside vent of ø125 (5ins) or
ø150mm (6ins).
The ducting used must be manufactured from fire retardent mate-
rial conforming to the relevant British Standard or DIN 4102-B1.
When the cooker hood is ducted to the outside the charcoal filter
must be removed.
When installing the ducted version, connect the hood to the chim-
ney using either a flexible or rigid pipe ø 150 or 120mm, the choice
of which is left to the installer.
To install a ø 150
• To install the dumper 10.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
To install a ø 120
• To install a ø 120 mm air exhaust connection, insert the reducer
flange 9 on the dumper 10.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove any activated charcoal filters.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
���
��
���
���
Fitting the Ducting
• To install the Ducting Version of the hood, the optional
Ducting chimney kit must be purchased.
Never do flambé cooking under this cooker hood.
Take extra care when frying and never leave frying
pans unattended during use, as over-heated fats and
oils can catch fire.
Do not leave naked flames under the cooker hood.
Ensure the hood is switched on before using the hob.
Ensure heating areas on your hob are covered with
pots and pans when using the hob and cooker hood
simultaneously.
Ensure not to damage the charcoal filter when
cleaning or replacing as the activated charcoal inside
is saturated with grease, which will stain if it comes
into contact with clothing or furnishings.
��
��
���
����
�����
��
��
�����
9