INSTALLATION
Necessary room for installation and maintenance
If possible, please remove the obstacles nearby to prevent the performance from being impeded by too little of air circulation . Leave
open two of the three directions(A,B,C) .
Moving and installing
Since the gravity center of this unit is not at its physical center, so please be careful when lifting it with a sling .
Never hold the air-in of the outdoor unit to prevent it from deforming .
Do not touch the fan with hands or other objects .
Do not lean it more than 45o, and do not lay it sidelong .
Please fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong wind.
Make concrete foundation . (Refer to chart 2)
Concrete foundation
1.
Foundation could be on flat and is recommended be 100-300mm higher than ground level.
2.
Install a drainage around foundation for smooth drain
3.
When installing the outdoor unit fix the unit by anchor bolts of M10
4.
When installing the unit on a roof or a veranda, drain water sometimes turns to ice on a cold morning . Therefore, avoid draining
in an area that people often use because it is slippery .
(Wall or obstacle)
B
Air inlet
A
DUCTAIR II - 0808-E
Air inlet
>60cm
C
Air outlet
Chart 20
Obstacle
Fix with bolt
Necessary width
Chart 2
Deep
foundation