STEP 1.
Make the gas connection between the manual shut off valve and regulator located inside
heater cabinet. Hold regulator when tightening connection to prevent damage to regulator
and internal tubing. See Figure 6 for completed installation.
NOTE:
All piping and connection must be checked for leaks by the installer. If connections are not
exposed, a pressure test must be run. The appliance and its individual shut off valve must
be disconnected from the gas supply piping system during any pressure testing at pressures
in excess of ½ psig (3.5 kPa). The appliance must be isolated from the gas supply piping
system by closing its individual manual shut off valve during any pressure testing of the gas
supply piping system at test pressures equal to or less than ½ psig (3.5kPa).
Outside Reg.
Supplied
by Gas Co.
Manual Shut Off
1/8" NPT Plug
FIGURE 6
This appliance is orificed at the factory for elevations up to 2,000 ft. If installed above 2,000 ft. the BTU
input must be reduced 4% per 1,000 ft. See the following orifice chart for the proper orifice for a specific
elevation. Orifice change must be done by a qualified installer or service technician.
Model No.
No.
BFT101
BFT201
BFT301
BFT102
BFT202
BFT302

GAS CONNECTION

Internal Regulator
(Supplied)
Union
Drip Leg
BURNER ORIFICE
SPECIFIC ELEVATION
0 to
2,000 -
2,000'
4,000'
1.55 mm
54
43
44
36
38
63
65
55
55
52
53
GAS PIPING WITH VF-FSK KIT
FIGURE 6A
4,000 -
6,000 -
6,000'
8,000'
NATURAL GAS
54
55
45
47
40
41
L.P. GAS
65
66
56
56
53
54
Page 10
Manual
Cut off
Valve
1/8" NPT
Pressure
Drip
Plug
Leg
8,000 -
10,000'
55
48
43
68
57
54