(3)BUZZER OPERATION CHECK
CONDITIONS
MEASURING
POINT
IC1 (No.23 Pin)
IC1 (No.22 Pin)
DISPLAY FUNCTION BUTTON RING
(DING~ DONG~)
0.05s
0.2s
5V
0V
5V
0V
2.66kh
z (DING~)
0.1s
1s
2.232kh
z (DONG~)
- 24 -
DOOR OPEN ALARM
(SCREECHING)
0.5s
0.5s
5V
0V
5V
0V
3.1kh
OFF
z
OFF
ov
ov