Sharp FU-S51A Operation Manual

Sharp FU-S51A Operation Manual

Air purifier free standing

Advertisement

Free Standing
*Plasmacluster is a trademark of
Sharp Corporation.
*Plasmacluster 是聲寶 公司的商標
R
AIR PURIFIER
OPERATION MANUAL
FU-S51A
FU-S51E

Advertisement

Table of Contents
loading

Summary of Contents for Sharp FU-S51A

  • Page 1 FU-S51A FU-S51E AIR PURIFIER OPERATION MANUAL Free Standing *Plasmacluster is a trademark of Sharp Corporation. *Plasmacluster 是聲寶 公司的商標...
  • Page 2 Please read before operating your new Air Purifier The air purifier draws in room air from its air intake, lets the air pass through a Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan.
  • Page 3: Table Of Contents

    Microbial Control High-efficiency particle collection in- cluding pollen and dust. Thank you for purchasing the SHARP Air Puri- fier. Please read this manual carefully for the cor- rect usage information. Before using this prod- uct, be sure to read the section: “Important Safety Instructions.”...
  • Page 4: Important Safety Instructions

    • Be cautious when cleaning the air purifier. Strong corrosive cleansers may damage the exterior. • Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service Centre for any problems, adjustments, or repairs. NOTE...
  • Page 5: Cautions Concerning Operation

    IMPORTANT SAFETY INSTRUCTIONS CAUTIONS CONCERNING OPERATION • Do not block the intake and air outlet. • Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam. •...
  • Page 6: Part Names

    PART NAMES MAIN UNIT DISPLAY AUTO Operation Indicator Light Pollen Mode Indicator Light Fan Speed Indicator Lights Plasmacluster Ion Mode Indicator Lights Plasmacluster Ion Mode Selection Button Mode Selection Button ION SHOWER Indicator Light ION SHOWER Mode Button ILLUSTRATIVE DIAGRAM Date Label Odour Sensor Main Unit...
  • Page 7: Back

    Plasmacluster Indicator Light (Please refer page E-9) Blue light When the Plasmacluster ion operation is in Clean Mode, or in AUTO Plasmaclus- ter Ion Mode and the air in the room is impure, the light will be activated and the unit will operate in Clean Mode.
  • Page 8: Preparation

    PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filters, they are installed in the main unit and packed in plastic bags. Be sure to remove the filters from the plastic bags before using the unit. Remove the filters Front Panel Remove the Front Panel.
  • Page 9 Install the filters Place the HEPA Filter into the main unit. (blue) Please make sure that the HEPA Filter(blue) and the tab is placed in HEPA Filter proper direction. Do not install the filter backwards or the unit will not operate properly. Band(blue) Place the Filter Support through the bands (2 places)
  • Page 10: Operation

    OPERATION MAIN UNIT OPERATION Mode Selection Button Plasmacluster Ion Mode Selection Button Power ON/OFF Button • Used to start operation (short beep) and stop operation (long beep) • Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. • Unless unplug the power cord, the operation starts in the previous mode the unit was operated in.
  • Page 11 Plasmacluster Indicator Light CLEAN - SIGN Light POWER ON/OFF Button ION SHOWER Mode Button ION SHOWER Mode Button When pushing the ION SHOWER Mode button, the ION SHOWER operation will be activated. (Direct start is available even when the unit is not turned on.) The concentrated Plasmacluster Ions (ION SHOWER) will be generated in the room like a shower for 15 minutes, repeating the airflow cycles...
  • Page 12: Care And Maintenance

    CARE AND MAINTENANCE To maintain optimum performance of this air purifier, please clean the unit including the sensor and filters periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. MAIN UNIT Care Cycle 1 month...
  • Page 13: Washable Active Carbon Filter Care

    WASHABLE ACTIVE CARBON FILTER CARE Care Cycle 2 months HAND WASH ONLY! DO NOT TUMBLE DRY! Remove excess water. The filter will be saturated with water after rinsing. To decrease drying time, wrap the filter in an old thick towel so that excess water can be removed.
  • Page 14: Filter Replacement Guidelines

    Please dispose of replaced filters according to the local disposal laws and regulations. HEPA Filter Materials: • Filter: Polypropylene • Frame: Polyester Active Carbon Filter Materials: • Deodorizer: Activated charcoal • Net: Polypropylene 60%, Polyester 40% SPECIFICATIONS FU-S51A Model 220V 50Hz Power supply Fan Speed Adjustment SILENT...
  • Page 15: Troubleshooting

    LAMP INDICATION REMEDY Fan motor disconnected or abnormal. Operation stops. The “Silent” Fan Speed Indica- • Pressing the POWER ON/OFF button will reset the error tor Light blinks. display, but if error occurs again, contact the Sharp Service Centre. E-13...
  • Page 16 • •...
  • Page 17 • • • • • • • • • • • • • • • • • •...
  • Page 18 • • • • • • • • • • • • • • • • •...
  • Page 19 • • • • • • • • • • • • • • •...
  • Page 21 • • •...
  • Page 22 Front Panel Filter Support HEPA Filter HEPA Filter Active Carbon Filter...
  • Page 23 HEPA Filter Band(blue) Filter Support Active Carbon Filter Filter Support Date Label Front Panel...
  • Page 24 • • • • •...
  • Page 25 • •...
  • Page 26 Washable Active Carbon Filter Sensor Cover Hole of Odour Sensor C-10...
  • Page 27 • • • • • C-11...
  • Page 28 • • • • • • • FU-S51A / 50 ( )x207 ( )x620 *1 • • C-12...
  • Page 29 • • • • • • • • • • • • • C-13...
  • Page 31 MEMO...
  • Page 32 SHARP CORPORATION Printed in Japan Printed in Japan TINS-A185KKRZ 05KK...