! Once the appliance has been installed, the power
EN
supply cable and the electrical socket must be
easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced
by authorised technicians only (see Assistance).
! The manufacturer declines any liability should
these safety measures not be observed.
Your appliance is supplied with a 13amp fused plug
that can be plugged into a 13amp socket for
immediate use. Before using the appliance please
read the instructions below.
WARNING:
THIS APPLIANCE MUST BE EARTHED.
Replacing fuse covers:
When replacing a faulty fuse, a 13amp ASTA
approved fuse to BS 1362 should always be used
and the fuse cover re-fitted.
If the fuse cover is lost, the plug must not be used
until a replacement is obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of
the correct colour as indicated by the coloured
marking or the colour that is embossed in words on
the base of the plug.
Changing the plug:
Removing the plug
If your appliance has a non-rewireable moulded plug
and you should wish to remove it to add a longer
cable or to re-route the mains cable through
partitions, units etc. please ensure that either:
-
The plug is replaced by a fused 13amp re-wireable
plug bearing the BSI mark of approval.
or
-
The mains cable is wired directly into a 13amp
cable outlet, controlled by a switch (in compliance
with BS 5733) which is accessible without moving
the appliance.
Disposing of the plug
Cut off and dispose of the supplied plug if it does
not fit your socket. The cable should be cut as close
as possible to the moulded plug.
Remove the fuse.
4
WARNING:
To avoid a shock hazard do not insert the
discarded plug into a socket anywhere else.
Fitting a new plug
IMPORTANT: : : : :
WIRES IN THE MAINS LEAD ARE COLOURED IN
ACCORDANCE WITH THE FOLLOWING CODE...
As the colours of the wires in the mains lead may
not correspond with the coloured markings
identifying the terminals in your plug, proceed as
follows:
-
Connect Green and Yellow wire to terminal
marked 'E' or
or coloured Green and Yellow.
-
Connect Brown wire to terminal marked 'L' or
coloured red or brown.
-
Connect Blue wire to terminal marked 'N' or
coloured Black or Blue.
If a 13amp plug (BS 1363) is used it must be
fitted with a 13amp fuse. A 15amp plug must be
protected by a 15amp fuse, either in the plug or
adaptor or at the distribution board.
If you are in any doubt about the electrical supply
to your machine, consult a qualified electrician
before use.
CE Marking certifies that this appliance conforms to
the following EEC directives :
Low Voltage Equipment - 73/23/EEC & 93/68 EEC
Electromagnetic Compatibility 89/336/EEC, 92/31/
EEC & 93/68/EEC
Green and Yellow - Earth
Blue - Neutral
Brown - Live

Hide quick links: