Connecting Input
Power
Table 3-1. Electrical Service
Requirements*
Have
only qualified
persons make
this installation.
1
Line Disconnect Device Of
Proper Rating
2
230 Volts AC Wall
Receptacle
3
Input
Conductors
4
Grounding
Conductor
Select
size
and
length
using
Table 3-1.
Conductor
rating
must
comply
with
national,
state, and
local electrical codes.
Install
and
connect
grounding
conductor and
input
conductors in
conduit
or
equivalent
between wall
receptacle
and
deenergized
line
disconnect device.
Connect
grounding
conductor
first,
then line
input
conductors.
Be
sure
grounding
conductor goes
to
an
earth
ground.
5
Overcurrent Protection
Select
type
and
size
using
Table 3-1.
Install into
deenergized
line disconnect device
(fused
dis
connect
switch
shown).
6
Input
Power
Plug
Turn ott unit
Power switch, and
connect
plug
to
wall
receptacle.
ssb2.2 12/94
Ref. ST-154 619-B
/
Ref.
ST-149 405-B
Input Voltage
200
230
460
575
Input Amperes
At Rated
Output
46
40
20
16
Max Recommended Standard Fuse Or Circuit
Breaker
Rating
In
Amperes
70
60
30
25
Mm
Input
Conductor Size In AWG/Kcmll
8
8
12
14
Max Recommended
Input
Conductor
Length
In
Feet
(Meters)
89(27)
117
(36)
188(57)
190(58)
Mm
Grounding
Conductor Size In AWG/KcmlI
8
10
12
14
Reference: 1993 National Electrical Code
(NEC).
9-0092J
5
3
Tools Needed:
Figure
3-6.
Input
Power Connections
OM-154
501
Page
7

Advertisement

Table of Contents