1-6-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
1
Turn the power OFF.
While measuring with an oscilloscope the output voltage of R6233 in the periphery of IC6203 on the YY-003 board, turn the
2
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
3
the camera control circuit (IC4201 of TT-003 board) periphery.
Note: When the lens block was replaced, execute a necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
1-6-2. E : 62 : 10 [Shift Lens Initializing Failure] Occurred
Connect the adjustment remote commander (RM-95 or NEW LANC JIG) and perform the following process.
Order Page Address Data
1
0
2
0
F
3
(7F)
F
4
(7F)
F
5
(7F)
F
6
(7F)
F
7
(7F)
F
8
(7F)
9
0
10
0
11
12
13
Note 1: Perform adjustment by referring to "SD Sensor Gradient Adjustment" in Service Manual, ADJ. After the adjustment, be
sure to perform "Optical Axis Adjustment" and "Angular Velocity Sensor Sensitivity Adjustment".
Note 2: When the lens block was replaced, execute a necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
HDR-FX7/FX7E_L2
01
01
10
07
04
Read the data value and assume it as D
Change the data and check that it has been changed. If no value changes or if value is 00 or FF, inspect
04
the EEPROM (IC4202 of TT-003 board). If value changes, proceed to the order 5.
04
D
Press PAUSE (Write) button.
04
05
Read the data value and assume it as D
Change the data and check that it has been changed. If no value changes or if value is 00 or FF, inspect
05
the EEPROM (IC4202 of TT-003 board). If value changes, proceed to the order 8.
05
D
Press PAUSE (Write) button.
05
10
00
01
00
Perform "PSD Sensor Gradient Adjustment". (Note 1)
Turn the power OFF and ON again.
Check that no error occurs. If an error occurs, replace the lens block (Note 2).