4) Communication failure details (Low-speed blinking: Flashes 3 times + High-speed blinking)
Error type
Expression of Central Icon LED
Initial communication
H: ON
reception failure
Flashes once
L: OFF
(High speed)
Start-up confirmation
H: ON
reception failure
Flashes twice
L: OFF
(High speed)
Regular communica-
H: ON
tion failure
L: OFF
Flashes 3 times
(High speed)
Other communica-
H: ON
tion failure
L: OFF
Flashes 5 times
(High speed)
5) Other failure details (Low-speed blinking: Flashes 4 times + High-speed blinking)
Error type
Expression of Central Icon LED
Monitor temperature
H: ON
failure
L: OFF
Flashes once
(High speed)
Main failure
H: ON
Flashes 3 times
L: OFF
(High speed)
Note: Basically, debug print logs are analyzed or
communication logs are analyzed by a bus monitor.
Initial communication from the main CPU is not received.
(Request for the monitor model No. is not received.)
→ Communication line failure or main CPU start-up failure
Start-up reason confirmation from the main CPU cannot be
received.
(Startup communication until start-up reason notification command
is not received.)
→ Main CPU start-up failure or monitor microprocessor reception
failure
Regular communication that is performed at 1 second intervals in
the normal operation is interrupted.
→ Main CPU operation failure or monitor microprocessor
reception failure
When a request (PM_REQ=H) is sent from the main microproces-
sor, the request command is not output from the main CPU, etc.
→ Main CPU operation failure or monitor microprocessor
reception failure
Note: Pins are monitor microprocessor pins unless otherwise
specified (IC2002).
If the panel temperature is 60°C or more for 15s or more in a row,
CAUTION appears on the OSD (flashes in red in the lower right
screen).
If the panel temperature is 60°C or more for 25s or more in a row,
error standby is activated.
(MONITOR MAX TEMP on page 13/21 of the adjustment process:
Change AD value for temperature failure): Thermistor
Main microprocessor detection error (CPU temperature error, etc.)
Details are displayed on page 1/21 of the adjustment process for
the main microprocessor.