Table 3-10. HMX6801+B2/C2 Read-Only Parameters—Remote Control Only (Continued)
Bank,
Rotary
Parameter Name
Switch
[RO]
Out Ch01 Format Fb
to
Out Ch08 Format Fb
[RO]
Output 01 Status
to
Output 08 Status
1 Parameters designated as read-only [RO] are only available from a remote CCS software control ap-
plication such as Pilot or Navigator
Table 3-11. Parameter Options - HMX6801+B4/C4
Bank, Rotary
Parameter
Switch
Name
0, 1
SDI IP Video Std
Set
50
Function
Reports the AES format of output
channels 01 to 08
Reports the status (peak/silence/normal)
of output channels 01 to 08
Function
Selects the SDI input video signal
standard
HMX6801+B2/C2 and HMX6801+B4/C4 Installation and Operation Manual
Options
• PCM
• Non-PCM
• Peak
• Silence
• Normal
Options
• Auto
• 1035I30
• 1035I29.97
• 1080I25 (295M)
• 1080I30
• 1080I29.97
• 1080I25
• 1080P30
• 1080P29.97
• 1080P25
• 1080P24
• 1080P23.98
• 720P60
• 720P59.94
• 720P50
• SD-525
• SD-625

Hide quick links: