Yamaha STAGEPAS 300 Service Manual page 24

Hide thumbs Also See for STAGEPAS 300:
Table of Contents

Advertisement

STAGEPAS 300
QQ
3 7 63 1515 0
ITEM
No.
3
INPUT SENSITIVITY
4
FREQUENCY
TE
L 13942296513
RESPONSE
5
TONE-CONTROL
CHARACTERISTIC
www
.
24
http://www.xiaoyu163.com
INPUT CONDITIONS
INPUT 1, 2, 3, 4 (Each)
INPUT=XLR
INPUT-SW=LINE
INPUT-LEVEL=MAX.
INPUT 1, 2, 3, 4 (Each)
INPUT=XLR
INPUT-SW=MIC
INPUT-LEVEL=MAX.
INPUT 1, 2, 3, 4 (Each)
INPUT=PHONE
INPUT-SW=LINE
INPUT-LEVEL=MAX.
INPUT 5 and 6, 7 and 8
(Each pair)
INPUT=PHONE, RCA
INPUT-LEVEL=MAX.
INPUT:
60 Hz
1, 2, 3, 4 (Each)
INPUT=XLR
INPUT-SW=LINE
10 KHz
INPUT-LEVEL=MAX.
INPUT:
60 Hz
5 and 6, 7 and 8
(Each pair)
INPUT=PHONE, RCA
10 KHz
INPUT-LEVEL=MAX.
INPUT 1, 2, 3, 4, 5, 6, 7, 8
(Each)
LOW=MIN.
REF: 30 Hz, LOW VR CENTER
INPUT 1, 2, 3, 4, 5, 6, 7, 8
(Each)
LOW=MAX.
REF: 30 Hz, LOW VR CENTER
INPUT 1, 2, 3, 4, 5, 6, 7, 8
(Each)
HIGH=MIN.
REF: 30 KHz, HIGH VR CENTER
INPUT 1, 2, 3, 4, 5, 6, 7, 8
(Each)
HIGH=MAX.
REF: 30 KHz, HIGH VR CENTER
INPUT1
x
ao
u163
y
HIGH, LOW VR CENTER
SPEECH/MUSIC=SPEECH
i
REF: 80 Hz, MUSIC MODE
http://www.xiaoyu163.com
2 9
8
OUTPUT CONDITIONS
SP OUT:
L, R
REF: 100 W OUTPUT
MONITOR OUT:
L
+4 dBu OUTPUT
(Load: 10 kΩ)
REC OUT:
L, R
-8 dBu OUTPUT
(Load: 10 kΩ)
MONITOR OUT:
L
+4 dBu OUTPUT
(Load: 10 kΩ)
L
L
SP OUT:
L, R
Q Q
3
6 7
1 3
1 5
REF: 1 W OUTPUT
SP OUT:
L, R
REF: 1 W OUTPUT
REF: 300 mV RECOUT
(Load: 10 kΩ)
co
.
9 4
2 8
NOMINAL
LIMIT
-23 dBu
-23 dBu±3 dB
-31 dBu
-31 dBu±3 dB
-31 dBu
-31 dBu±3 dB
-61 dBu
-61 dBu±3 dB
-21 dBu
-21 dBu±3 dB
-21 dBu
-21 dBu±3 dB
+4.0 dB
+4.0±2 dB
0 5
8
2 9
9 4
2 8
0 dB
0±2 dB
+4.0 dB
+4.0±2 dB
0 dB
0±2 dB
-15.0 dB
-15.0±2 dB
+15.0 dB
+15.0±2 dB
-15.0 dB
-15.0±2 dB
+15.0 dB
+15.0±2 dB
m
-3.0 dB
-3.0±2 dB
9 9
9 9

Hide quick links: