Summary of Contents for German Light Product Mini Patend

  • Page 1 Instruction Manual from software version 1.07 (instruction version 1.11) e-mail: service@glp.de Internet: http://www.GLP.de...
  • Page 2 German Light Production (V1.11)
  • Page 3: Table Of Contents

    Table of contents Description of Device....................5 1.1 Safety Instructions ....................6 Preparation and Installation ...................7 2.1 Mounting ......................7 2.1.1 Clamps ....................7 2.1.2 Mounting plate..................8 2.2 Secure the D ................8 2.3 Connections......................9 2.3.1 Power supply..................9 2.3.2 DMX .......................9 2.4 Fuse........................9 The Menu Field ......................10 (D001) 3.1 Adjust the DMX- Address ..............11...
  • Page 4 5.3 Lamp adjustment ....................19 Maintenance and Cleaning the D .............20 6.1 Safety Regulations..................20 6.2 Circumference and Interval (rule-of-thumb) ............20 6.3 Cleaning the Optical System................21 Technical Specification ..................22 Index ........................23 German Light Production (V1.11)
  • Page 5: Description Of Device

    Description of Device 1. Roto Head 2. Mirror 3. Base 4. Carrying handles 5. Connections 1. Mode- button 6. Microphone Sensitivity 10. Fan (air inlet) 2. Enter- button 7. Software-Update connector 11. Power On/Off 3. Up- button 8. DMX- Input 12.
  • Page 6: Safety Instructions

    1.1 Safety Instructions D is a High-Tech product. To guarantee a smooth operation it is necessary to keep the following rules. The manufacturer of this device will not take responsibility of damages through disregard of the information given in this manual.
  • Page 7: Preparation And Installation

    Preparation and Installation 2.1 Mounting D is fully operational whether it hangs or is mounted to the wall. It can also be operated while standing on the floor. Keep a safety distance of 0.5 m towards any easy inflammable materials (decoration etc.). Install a safety wire that can hold at least 10 times the weight of the fixture.
  • Page 8: Mounting Plate

    2.1.2 Mounting plate For a permanent installation of the D you can use a optional mounting plate to fix the unit on a wall. The plate uses 2x screws M6x10 and one M10x16 (the mounting plates are included in the delivery). 2.2 Secure the Regardless of the rigging of the D you have to use a stipulated safety...
  • Page 9: Connections

    2.3 Connections 2.3.1 Power supply 230 Volt, 50 Hz, Connected load 300W <=> 2 A (power factor corrected). or 115V, 60 Hz, Connected load 300W <=> 3.15 A (power factor corrected). Please see printing on the case for the right Power supply ! 2.3.2 DMX DMX 512 Standard input/output.
  • Page 10: The Menu Field

    The Menu Field The control panel is located at the side part of the base. It allows you to make all necessary adjustments of the With the Mode-key you get into the main menu. Afterwards you can navigate through the menu with the Up/Down-keys. Push the Enter-key to get in the next menu level or to confirm your settings.
  • Page 11: Adjust The Dmx- Address

    (D001) 3.1 Adjust the DMX- Address Right after turning on the D you can see the current DMX- address. If there is no DMX- signal the display flashes. D001 For the address setting please follow this procedure: 1. Switch ON the D and wait until the fixture reset has finished (the display is showing ' 2.
  • Page 12: Lamp On/Off (Lamp)

    (LAMP) 3.4 Lamp On/Off LAMP Off. Use the Up/Down-keys to select lamp or lamp Press Enter to confirm or Mode to cancel and return to the main menu. (The lamp command is only working if the shutter is closed at the same time. Use an external controller or the manual drive mode, see 3.9.1) (RESE) 3.5 Reset...
  • Page 13: Special Functions (Spec)

    (SPEC) 3.9 Special Functions SPEC This menu allows you to enter further special functions of the In detail they are: (MANU) 3.9.1 Manual Drive MANU This function allows you to drive all the fixture functions manually. Select the desired function with the Up/Down-keys and confirm with Enter. Now choose the desired value with the Up/Down-keys and confirm again with Enter or cancel and return to the menu with the Mode-key.
  • Page 14: Lamp Off Via Dmx

    (DLOF) 3.9.3 Lamp Off via DMX DLOF This function enables you to switch off the lamp via DMX or not. Use the Up/Down-keys to select if you want to switch off the lamp via DMX or if you don't want this function. Press Enter to confirm or Mode to cancel and return to the menu.
  • Page 15: Adjustments And Calibrations

    (ADJU) 3.9.6 Adjustments and Calibrations ADJU By this function you can adjust and calibrate the positions of the different wheels and other motors. This can be necessary after a service or repair work. For this function you have to entry the fixture code. This work should be done only by authorized persons.
  • Page 16: Error And Information Messages

    3.10 Error and Information Messages RsER This message informs you that one of the fixture function wasn’t able to complete its reset successfully (magnetic sensor, stepping motor, driver on the PCB, cables, etc.). Repair the defect and start the fixture again. DMX Channel Selection (DMX Protocol) Channel Function...
  • Page 17 Channel Function Time and Value color 13 / color 14 54..55 36..37 21,4 color 14 56..57 38..39 22,2 color 14 / color 15 58..59 3A..3B 22,9 color 15 60..61 3C..3D 23,7 color 15 / color 16 62..63 3E..3F 24,5 color 16 64..65 40..41 25,3...
  • Page 18 Channel Function Time and Value near - far 0..255 0..FF 0..100 10) Focus Pan/Tilt relative movement 0..1 00..01 0..0,5 11) Speed Speed, slow - fast 2..255 02..FF 1..100 no movement 12) Move- ment Movement Size Phase 0° 01..01 01..01 90° 02..03 02..03 180°...
  • Page 19: Change The Lamp

    Change the Lamp For a troublefree operation please read this chapter carefully and follow all instructions. 5.1 Safety Regulations • Pull out the main plug! • Wait at least 20 minutes after the last operation to cool down the fixture. •...
  • Page 20: Maintenance And Cleaning The M I N I P A T E Nd

    LAMP 1. Strike the lamp (for example in the menu) and wait a while until full intensity of the lamp. 2. Direct the beam straight on a flat and bright surface/wall (beam open, white, no gobo, no effects). 3. If the Hot-Spot (brightest part of the beam) is not in the middle and the beam is not max.
  • Page 21: Cleaning The Optical System

    Position Interval In this way Outside optic weekly soft cloth and glass cleaning fluid Color filter monthly soft cloth and glass cleaning fluid Gobos yearly vacuum cleaner, airbrush, etc. Glass gobos monthly soft cloth and glass cleaning fluid Prism monthly soft cloth and glass cleaning fluid Dimmer/Shutter yearly...
  • Page 22: Technical Specification

    Technical Specification Power supply Power consumption 300 Watt (power factor corrected) EU-model AC 230V / 50 Hz~ Fuse protection T2A, 250V, 5x20 mm (fine-wire fuse) US-model AC 115V / 60 Hz~ Fuse protection T3.15A, 115V, 5x20 mm (fine-wire fuse) Lamp Type 1 Philips, CDM/SA-T 150W, 6000h Osram, HSD150, 3000h...
  • Page 23: Index

    Index Adjustments ........... 15 Lamp..............19 aspheric lens............ 21 Audio..............11 Maintenance........... 20 Measures............22 BGV C1.............. 7 Menu Field............10 Mounting............7 Mounting plate..........8 Calibrations ............ 15 Clamps............... 7 Connected load..........9 Pan- movement ..........22 Permanent installation ........8 Power supply .............