Special functions

Auto Changeover (Setup Function 0300): When set to Auto, the thermostat automatically selects heat-
ing or cooling depending on the indoor temperature. Heat and cool settings must be at least 2 degrees
apart.
Adaptive Intelligent Recovery (Setup Function 0530): Allows the thermostat to "learn" how long the
furnace and air conditioner take to reach programmed temperature settings, so the temperature is
reached at the scheduled time.
Compressor Protection (Setup Function 0580): Forces the compressor to wait a few minutes before
restarting, to prevent damage. During this time, the message "Wait" is on the display.
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Cover plate* ............................................................. Part Number 32003796-001
*(Use to cover marks left by old thermostats.)

Specifications

Temperature Ranges
• Heat: 40° to 90°F (4.5° to 32°C)
• Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
• 0° to 120°F (-18° to 48.9°C)
Shipping Temperature
• -30° to 150°F (-34° to 66°C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Physical Dimensions
• 4-23/25" H x 6-2/5" W x 1-19/46" D
• 125 mm H x 166 mm W x 36 mm D

Optional THP9045 Wiring Module

The THP9045 Wiring Module is designed to be used with applicable thermostats in 1 Heat/1
Cool retrofit applications where only 4 wires are available. The K terminal on the thermostat can
be used to operate both the fan and compressor on a single wire, and the module is designed to
receive the signal from the K terminal, split that signal and reroute it to operate the compressor,
and/or fan for normal operation. See the THP9045 manual for further details.
69-2486—07
Electrical Ratings
Terminal
Voltage (50/60Hz)
W Heating
(Powerpile)
W2 Heating
Y Cooling
Y2 Cooling
Aux Auxiliary heat
O/B Changeover
E Emergency heat
L Heat pump reset
14
Running Current
20-30 Vac
750 mV DC
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
0.02-1.0 A
100 mA DC
0.02-0.6 A
0.02-1.0 A
0.02-0.6 A
0.02-1.0 A
0.02-0.6 A
0.02-1.0 A