Mitsubishi Electric SLZ-KA25VA.TH Technical & Service Manual page 22

Series slz ceiling cassettes r410a split-type, heat pump air conditioners
Table of Contents

Advertisement

Mitsubishi ilmalämpöpumput korjaa ja huoltaa: Jäähdytinpalvelu RefGroup Oy (pääkaupunkiseutu)
OPERATING PROCEDURE
5. Remove the room temperature thermistor (TH1)
(1) Remove the panel. (Refer to 3)
(2) Pull out the room temperature thermistor from the drain
pan.
(3) Remove the 2 screws fixed to the control box cover, and
remove the control box cover.
(4) Remove the connector (CN20) from the indoor controller
board, and disconnect the room temperature thermistor.
6. Remove the drain pan
(1) Remove the panel. (Refer to 3)
(2) Remove the room temperature thermistor and the 2 lead
wires held with fastener; wireless controller board relay
connector (9P red) and panel relay connector (10P white).
(3) Remove the 4 screws fixed to the drain pan, and remove
the drain pan.
(4) Remove the fan guard. (Refer to 2)
7. Removing the pipe temperature thermistor/liquid (TH2)
and condenser/evaporator temperature thermistor (TH5)
(1) Remove the panel. (Refer to 3)
(2) Remove the drain pan. (Refer to 6)
(3) Disconnect the indoor coil thermistor from the holder.
(4) Remove the 3 screws fixed to the piping cover, and
remove the piping cover. (See photo 9)
(5) Remove the 2 screws fixed to the control box cover, and
remove the control box cover.
Pipe temperature thermistor/liquid (TH2)
(6) Remove the connector (CN21) from the indoor controller
board, and disconnect the pipe temperature thermistor/liquid.
Condenser/evaporator temperature thermistor (TH5)
(6) Remove the connector (CN29) from the indoor controller
board, and disconnect the condenser/evaporator temperature
thermistor.
8. Remove the fan motor (MF)
(1) Remove the panel. (Refer to 3)
(2) Remove the drain pan. (Refer to 6)
(3) Remove the nut and the washer from the turbo fan, and
remove the turbo fan.
(4) Remove the 2 screws fixed to the control box cover, and
remove the control box cover.
(5) Disconnect the connectors of the (fan 1) and the (fan 2)
from the indoor controller board.
(6) Remove the 3 screws fixed to the piping cover, and
remove the piping cover. (See photo 9)
(7) Remove the 6 screws fixed to the flat plate, and remove
the flat plate.
(8) Disconnect the lead wires to the direction of the fan motor,
and remove the 3 nuts of the fan motor.
PHOTOS&ILLUSTRATIONS
Photo 4
Screw
Room
temperature
thermistor
(TH1)
Screw
Photo 5
Pipe temperature
thermistor/liquid
(TH2)
Photo 6
Screws
Lead
wires
Screw
www.ilmalämpöpumput.com
22
Connectors
Drain plug
Control box
Fan guard
Control box
Condenser/evaporator
temperature thermistor
(TH5)
Screw
Flat plate
Nut
Nut
Screw
Drain pan
Screw
Fan motor
(MF)
Nut
Screws