User's Manual
MOD9200LON LONWORKS® Transceiver
Configuration Software
Setup & Configuration

Advertisement

Table of Contents
loading

Summary of Contents for aci MOD9200LON LONWORKS

  • Page 1 User’s Manual MOD9200LON LONWORKS® Transceiver Configuration Software Setup & Configuration...
  • Page 2 9. Termination This License Agreement is e_ective until it is terminated. You may terminate this License Agreement at any time by destroying or returning to ACI all copies of the Product and Documentation in your possession or under your control. ACI may terminate this License Agreement for any reason, including, but not limited to, if ACI _nds that you have violated any of the terms of this License Agreement.
  • Page 3: Table Of Contents

    Sending The Configuration File To The MOD9200 ............24 Activating The Config File ....................26 IV. Data Acquisition ........................27 LONWORKS Protocol ...................... 27 MOD9200LON LonWorks Transceiver Parameters ............. 27 • The Input Registers ....................... 28 • The Digital Output (Coil) Registers ................28 •...
  • Page 4: Introduction

    • Receives input from up to 50 remote wireless sensor modules and/or wireless output modules (RD2402 & RD2432) per Transceiver • ACI signal repeater/router RR2552 can be used to extend the wireless sensor transmission distance if needed • FTT-10 (Free Topology Twisted Pair) phyical network connection •...
  • Page 5: Lon Transceiver Installation & Network Setup

    MOD9000LON Receiver Installation & Configuration II. LON Transceiver Installation & Network Setup a. Transceiver Installation • Choose a location close to the LonWorks® network connection awat from the ground. • Mount the Transceiver on the wall using four #8 screws. •...
  • Page 6: Network Setup For Transceiver Configuration

    255.255.255.0. • The IP Address can be changed by changing the IP Address in the Transceiver Config File. Open either an existing config file or a new config file using the ACI Programmer Software. • Click on Settings > TCP/IP Transport.
  • Page 7: Manually Resetting The Factory Default Ip Address

    MOD9000LON Receiver Installation & Configuration • Our recommendation is not to change the default factory IP address of the transceiver, since the Ethernet connection is used to configure the transceiver only and will not be required when the LON network is up and running. •...
  • Page 8: Configuration Software

    MOD9000LON Receiver Installation & Configuration III. Configuration Software a. Configuration Software Description • The data registers of the Transceiver need to be configured prior to use. The configuration program “Trs Programmer.exe” can be found on CD ROM in packaging, or can be downloaded from our website ‘www.workaci.com’. The download instructions are included in the shipping document of the MOD9200 Transceiver.
  • Page 9: Creating A Mod9200 Configuration File

    MOD9000LON Receiver Installation & Configuration d. Creating A MOD9200 Configuration File • To create a new MOD9200 configuration file open the Trs Programmer by clicking on Start > Programs > Trs Programmer 6.XX. • To open a new configuration table Click on File > New Transceiver Config File. A blank configuration table will open.
  • Page 10: Input Register Configuration

    MOD9000LON Receiver Installation & Configuration e. Input Register Configuration • Each row of the configuration table is a unique data register having eight special attributes. -- Identifies the function of the register – Analog or FUNCTION Digital (Discrete) Note: If selecting the Digital (Discrete) function, be sure to set the appropriate Digital Capture Time (Page 15) REG ADDRESS...
  • Page 11 MOD9000LON Receiver Installation & Configuration • First we will assign the REG FUNCTION by clicking in the REG FUNCTION cell to open a drop down menu. Select the appropriate function. • Use the mouse to move to the next column to assign the REG ADDRESS by clicking in the cell.
  • Page 12 To select the address, click on the appropriate ID in the drop down menu. Each ACI transmitter is factory configured with a unique ID – refer to the sensor product data sheet for the location of the transmitter ID.
  • Page 13 MOD9000LON Receiver Installation & Configuration • Assign the appropriate sensor transmission channel to the data register by clicking in the cell to open a drop down menu. Click on the appropriate transmission channel (01 to 04) to select. AUTOMATION COMPONENTS, INC Version : 1.0 2305 Pleasant View Road I0000675...
  • Page 14 MOD9000LON Receiver Installation & Configuration The active transmission channels are factory configured as follows: Device Analog CH-01 Analog CH-02 Digital CH-01 WT2630A Space Temp (Therm 20K) WT2630B Space Temp SetPoint Override (Discrete) (Therm 20K) (Analog) See page 15 to set the Digital Capture Time WT2630C Space Temp...
  • Page 15: Digital Output (Coil) Register Configuration

    MOD9000LON Receiver Installation & Configuration • The completed configuration example for an office building is as follows: • The columns may be resized by placing the cursor over one side of the column. When the cursor changes to two arrows, hold down the left mouse button and drag the side of the column to resize it.
  • Page 16 MOD9000LON Receiver Installation & Configuration • Again use the mouse to move to the next column. Enter a GROUP NAME, if desired, for the data set by typing the group name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons in the Group Name.
  • Page 17: Analog Output (Holding) Register Configuration

    MOD9000LON Receiver Installation & Configuration • Assign the appropriate digital or relay output “TRANS CHAN” to the data register by clicking in the cell to open a drop down menu. Click on the appropriate transmission channel (01 to 04) to select. •...
  • Page 18 MOD9000LON Receiver Installation & Configuration • First we will assign the REG ADDRESS by clicking in the cell. Before entering register addresses, ensure the “RegisterEntry” AutoSet is turned off as shown: • Enter the Register address in the REG ADDRESS window. The valid range is 0 to 49. •...
  • Page 19 MOD9000LON Receiver Installation & Configuration • Assign a sensor/transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop down menu. This is the device ID of the remote output devices (RD2432). Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell.
  • Page 20: Setting The Mesh Network Id For The Repeater/Router Devices

    MOD9000LON Receiver Installation & Configuration h. Setting the Mesh Network ID for the repeater/router devices • The mesh network ID of the MOD9200 Gateway can be set to specific network # from 1 to 64. The MOD9200 functions as a network coordinator. Any repeater/router that has the same network ID will be able to communicate and channel sensor information to the MOD9200 i.
  • Page 21 • Digital Scaling On check box – Should be checked when configuring the MOD9200BNT BACnet® transceiver or the MOD9200LON LonWorks® Transceiver. • Units - Select the appropriate default temperature scale F/C. • Register Value When Sensor Lost – The user has the options to select whether the sensor value should remain unchanged or set to 19999 when the communication link is lost with the sensor (after the transmitter timeout period).
  • Page 22: Configuring The Transceiver For Internal Network

    MOD9000LON Receiver Installation & Configuration j. Configuring The Transceiver For Internal Network • The Transceiver needs to be assigned an Identifier Address for device internal use. To enter the Transceiver Unit ID into the Configuration File click on the Menu Comm > Unit Identifier.
  • Page 23 MOD9000LON Receiver Installation & Configuration • Use the Serial Comm Port configuration dialog box to select the appropriate internal communication parameters (Connect Speed, Connect Preferences, and Transport Mode) for the Transceiver. • The MOD9200LON requires internal communication parameters to be set as follows: Maximum Speed = 38400 BPS (This communication speed is set for internal use by the MOD9200LON Transceiver and it will not change the external LonWorks...
  • Page 24: Sending The Configuration File To The Mod9200

    MOD9000LON Receiver Installation & Configuration k. Sending The Configuration File To The MOD9200 • Before sending the file to the MOD9200, it is important to ensure that the “Serial Transport” setting is checked as shown: • Always save the configuration file to the folder “trs” before sending it to the MOD9200 Transceiver.
  • Page 25 MOD9000LON Receiver Installation & Configuration • Click on “Select File” and a window will open. Move to the Trs directory and select the appropriate file from the list. • Click on “Open” to automatically enter the selected file path as the File Name. •...
  • Page 26: Activating The Config File

    MOD9000LON Receiver Installation & Configuration • Click on “Connect” and the status of the connection will be displayed in the Comm Status window. When the Transceiver is connected click on “Send File” to the send the config file to the Transceiver. l.
  • Page 27: Data Acquisition

    MOD9200LON LonWorks Transceiver Parameters • The MOD9200LON Transceiver is an application specific FTT-10 (Free Topology Twisted-Pair) network device communicating at 78 KBPS. It receives data from up to fifty (50) wireless sensors and updates its data registers on a real time basis.
  • Page 28: The Input Registers

    MOD9000LON Receiver Installation & Configuration • Input/Output Types Supported: - Analog and Digital Inputs – Input Register 01 to 100 (NVOs) - Digital (Relay) Outputs – Digital Output (Coil) register 01 to 50 (NVIs) - Analog Outputs – Analog Output (Holding) register 01 to 50 (NVIs) •...
  • Page 29: The Alarm Registers

    MOD9000LON Receiver Installation & Configuration executed the command issued by the MOD9200, It will send a feedback status of the analog output value to the MOD9200. • The Alarm Registers The nvoAlm01 through nvoAlm100 are the alarm registers for all the input and output data points.
  • Page 30: Quick Setup Instructions

    MOD9000LON Receiver Installation & Configuration Example 1 – nvoAlm08 returns a value of 33 representing Input Register 08 (Low Battery Alarm), Digital Output 08 (Normal) & Analog Output 08 (Lost Communication). Example 2 – nvoAlm08 returns a value of 40 representing Input Register 08 (Normal), Digital Output 08 (Lost Communication) &...
  • Page 31: Installing The Ftt-10 Network

    MOD9000LON Receiver Installation & Configuration b. Installing the FTT-10 Network 1. Choose a location close to the LonWorks® network connection and away from the ground. 2. Mount the Transceiver on the wall using four #8 screws. 3. 24 VAC Input - Connect 24VAC 60 Hz and earth ground to the input terminals using 20 AWG wire as shown in the product data sheet.
  • Page 32: Available Mod9200Lon Models

    MOD9000LON Receiver Installation & Configuration APPENDIX A Available MOD9200LON models MOD9200LON-A Up to 30 wireless wall temperature sensors (WT2630A,B&C, FT2630A, DT2630A, & OST2630) with setpoint adjustments and/or push button override switches, up to 6 humidity sensors and up to 4 digital status inputs. Up to 50 wireless remote digital outputs and 50 wireless remote analog outputs.
  • Page 33 MOD9000LON Receiver Installation & Configuration For more information, please contact: 2305 Pleasant View Rd. Middleton, WI 53562 Telephone: 1-608-831-2585 www.workaci.com AUTOMATION COMPONENTS, INC Version : 1.0 2305 Pleasant View Road I0000675 Middleton, Wisconsin 53562 Page 33 of 33 www.workaci.com (888) 967-5224...