Appliance And Vent Clearances - Lennox Hearth Products Adagio ADAGIO-EN Installation Instructions Manual

Direct-vent gas fireplace heaters
Table of Contents

Advertisement

APPLIANCE AND VENT CLEARANCES

The appliance is approved with zero clearance to
combustible materials on all sides (as detailed
in Table 6), with the following exception: When
the unit is installed with one side flush with a
wall, the wall on the other side of the unit must
not extend beyond the front edge of the unit. In
addition, when the unit is recessed, the side walls
surrounding the unit must not extend beyond
the front edge of the unit. See Figure 1.
MINIMUM CLEARANCES
Back
Sides
Top Spacers
Floor
From Bottom of Unit
To Ceiling
Vent
1 (25.4)
SERVICE CLEARANCES
Front
 feet (0.9 meters)
Table 6
*Note: 3 in. (75 mm) above any horizontal vent
component. See Note
u
**Note: See Page 9, Step 1 for clearance
requirements to the nailing flange located at
each side of the unit and any screw heads
adjacent to it.
***Note: To ensure proper fit of the facade
(required - sold separately). The appliance
base will need to be elevated 3/4" minimum
above the floor to allow for the proper fit of the
facade (i.e. use 3/4" board as platform).
SHELF HEIGHT
To provide for the lowest possible shelf sur-
face, the venting attached to the top vent
should be routed in a way to minimize ob-
structions to the space above the appliance.
Do not insulate the space between the appli-
ance and the area above it (see Figure 2).
The minimum height from the base of the ap-
pliance to the underside of combustible ma-
terials used to construct a utility shelf in this
fashion is shown in the table in Figure 2.
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Inches (millimeters)
1/2 in. (1 mm)
1/2 in. (1 mm)**
0 in. (0 mm)
0 in. (0 mm)***
64 in. (1626 mm)
Figure 2 - Minimum Shelf Height Above Fireplace
 (76)
*
Top
Sides & Bottom
Feet (meters)
in Figure 2.
Figure 3 - Mantel Clearances - Inches (millimeters)
Combustible materials
may project beyond the
sides of the fireplace
opening as long as
they are kept within
the shaded areas il-
lustrated here.
At 14" minimum side
wall clearance, a
combustible wall may
project to any length
Side Wall Clearances
Figure 4
MODELS
Adagio-MN
Adagio-MP
Adagio-EN
Combustible Shelf Height
Inches (millimeters)
Top Vent - with One 90 Degree Elbow
Secure Vent
Secure Flex (flex elbow)
*52 (121)
*5-/4 (165)
* Includes 4" clearance to combustibles
(required above vent components)
u
4" clearance is required above the elbow
for installations that require an elbow at the
top of the unit and that ends in a horizontal
termination.
16
(406)
14
(356)
12
(305)
2" (51) Minimum
Clearance to Combustibles
Combustible Materials Allowed
In Shaded Area "Safe Zone"
17"
(432)
Do not insulate the
space between the
appliance and the
area above it.
Header
Drywall
*Shelf Height
(see table)
Shelf Above Fireplace - Top Vent
Mantel Clearances
Inches (mm)
12 (305) Mantel
10 (254) Mantel
8 (203) Mantel
6 (152) Mantel
4 (102) Mantel
10
2 (51) Mantel
(254)
8
(203)
6
(152)
12" (305)
5"
°
45
(127)
inches (millimeters)
Min. Distance
8-1/4" (210) to
Protected Side Wall
Side
Wall
Side
Wall
Min. Distance to
14" (356)
Unprotected Side Wall
4"
(102mm)
Top Spacers
Top Of
Appliance
Top View Of
Fireplace