2. Turn on the power. Vent motor will turn on and the draft control door will open widely.
Final adjustment of draft system:
3. Light stove. While fire is at maximum readjust Direct Vent value to within ½" of fully closed.
OPERATION -
ATTENTION: Always have a working Carbon Monoxide alarm to alert you to unsafe levels of dangerous
carbon monoxide.
Once setup and adjusted, no further adjustment is necessary. The vent motor operates at all times the stove is on.
MAINTENANCE -
Monthly:
Visually check that vent system pipe interior is free of ash accumulation.
Ensure Vent motor vents are free of dust or obstruction.
Ensure that Draft Control door operates freely.
TROUBLESHOOTING –
Symptom
Fire is out. All motors are off.
Draft Door is wide open.
Vent motor is at full speed.
Sulfur Smell or CO Detector Alert
Draft Door is closed. Draft Inducer
Fan is operating properly
Website: www.ReadingStove.com
Cause and Remedy
1. Turn off Pel-trol. 2. Check for blocked or plugged stove and vent
piping. 3. Test Vent motor from separate power source. 4. Reset
Fume Switch. 5. Turn on Pel-trol and verify operation and free
operation of Draft Control door.
1. Adjust Barometric Damper
1. Shutdown application and ensure that vent system is free of ash or
obstruction. 2. Perform Setup and Adjustment procedure.
1. Shutdown appliance and ensure that vent system is free of ash or
obstruction. 2. Perform Setup and Adjustment procedure. 3. Is
length of vent piping more than allowed?