6. Specifications

MODEL
VA
Capacity
W
INPUT
Rated
voltage
Low Line
Transfer
Voltage
Low Line
Range
Comeback
High Line
Transfer
High Line
Comeback
Frequency Range
Power Factor
OUTPUT
Output Voltage
AC Voltage Regulation
Frequency Range
Frequency Range
Current Crest Ratio (CF)
Harmonic Distortion
(THDU)
AC to DC
Transfer
Inverter to
Time
Bypass
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
Battery Mode
BATTERY
Battery Type
Numbers
Typical Recharge Time
Charging Current
(max.)
Charging Voltage
INDICATORS
LCD
ALARM
Battery Mode
Low Battery
Overload
Fault
PHYSICAL
Dimension,
DxWxH (mm)
Net Weight (kgs)
ENVIRONMENT
Humidity
Noise Level
MANAGEMENT
Smart RS-232/USB
Optional SNMP
*Derate capacity to 95% when the output voltage is adjusted to 115VAC, derate capacity to 90% when the output voltage is
adjusted to 110VAC and derate capacity to 80% when the output voltage is adjusted to 100VAC.
DC1000RT
DC1000RTX
1000 VA
1000 VA
800 W
800W
(based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0)
≦ 2% (Linear load)
8% max (Batt. mode before shut down)
86% (typical), 88% (peak)
83% (typical), 86% (peak)
12V/9Ah
2
4 hours recover to 90% capacity (for standard model only)
1 A
27.4 VDC ± 1%
UPS status, Load level, Battery level, Input/Output/battery info, Discharge time and Fault indicators
380 x 438 x 88
13.2
Supports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC
Power management from SNMP manager and web browser
DC1500RT
DC1500RTX
1500 VA
1500 VA
1200 W
1200 W
100VAC-120VAC
80 VAC/70 VAC/60 VAC/55 VAC ± 5 %
85 VAC/75 VAC/65 VAC/60 VAC ± 5 %
150 VAC ± 5 %
142 VAC ± 5 %
40Hz ~ 70Hz
≧0.99 @normal voltage
100*/110*/115*/120VAC
± 1%
47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
50Hz  0.5% or 60Hz  0.5% (Bat. Mode)
5:1 (max.)
Zero
4 ms (Typical)
Pure Sine wave
12V/9Ah
3
1 A
41.1 VDC ± 1%
Sounding every 4 seconds
Sounding every second
Sounding twice every second
Continuously sounding
480 x 438 x 88
18.9
20-90 % RH @ 0- 40°C (non-condensing)
Less than 50dBA @ 1 Meter
22
DC2000RT
DC2000RTX
2000 VA
2000 VA
1600 W
1600 W
≦ 2% (Linear load)
8% max (Batt. mode before shut down)
88% (typical), 90% (peak)
85% (typical), 88% (peak)
12V/9Ah
4
1 A
54.7 VDC ± 1%
480 x 438 x 88
21.4
DC3000RT
DC3000RTX
3000 VA
3000 VA
2400 W
2400 W
12V/9Ah
6
1 A
82.1VDC ± 1%
600 x 438 x 88
29.6