Scanner Configuration To The Host System - Metrologic IS4225 ScanGlove Installation And User Manual

Laser bar code scanner
Hide thumbs Also See for IS4225 ScanGlove:
Table of Contents

Advertisement

S
C
CANNER
ONFIGURATION TO THE
The IS4225 is shipped from the factory pre-configured to a set of default
parameters. It may be necessary to change the default parameters to match the
host system's requirements or to enable additional scanner functions. For a list
of possible parameter settings, refer to the Default Settings section of this guide.
Important notes for the -07, IS4225 USB Interfaces.
The IS4225-07 is pre-configured for USB Emulation before leaving the
factory. If the recall defaults bar code is scanned the unit must be
re-configured for USB Emulation before enabling or disabling any
additional features documented in the MetroSelect Single-Line
Configuration Guide (
To re-configure the unit for USB Keyboard Emulation or USB POS
Emulation refer to the IS4225 USB Configuration Addendum
(
00-02259).
MLPN
To modify the scanner's default parameters follow the steps below using the
bar codes located in the MetroSelect Single-Line Configuration Guide
(
00-02544).
MLPN
1.
Scan the
ENTER CONFIGURATION MODE
The scanner will beep three times.
2.
Scan the bar code(s) for the desired parameter(s).
The scanner will beep once.
3.
Scan the
EXIT CONFIGURATION MODE
parameter settings. The scanner will beep three times.
If during the configuration process, there is a need to return the
scanner to the original factory settings, scan the recall defaults bar
code in the MetroSelect Configuration Guide. All settings selected
during that session or any previous sessions are discarded when you
scan the recall defaults code.
Please read the warning above for the IS4225-07 model before using
the recall defaults bar code.
H
OST
00-02544).
MLPN
bar code to enter configuration mode.
bar code to exit and save the new