Page 1
The information in this documentation is supplied without warranty of any kind, either directly or indirectly, and is subject to change without prior written notice. SWISSON, its employees or appointed representatives will not be held responsible for any damages to software, hardware, or data, arising as a direct or indirect result of the product(s) mentioned herein.
Do not operate the device if any cover or component is missing damaged or deformed. Refer any service operation not descriped is this manual to Swisson. Provide unrestricted airflow arround the device. Do not operate the device if the abient temperatue exceeds 55 C (131 F).
Unpacking The XRC-200 is packaged in a cardboard box. The following items are included: - The device - This user manual Mains Connection Two different mains connections are available: The US versions are delivered by Swisson with a "Edison Plug" (NEMA-5-15).
Page 6
Selection buttons. These buttons are used to select a sequence, a playlist or to enter numeric values. Cancel button. This button is used to abort processes and to close dialogs. Ok button. This button is used to confirm. LCD screen. Step backward whithin plalist.
Recording a sequence Make sure, that the XRC-200 is in NORMAL mode (see p. 11) , before trying to record. Hint: This is the case after resetting the XRC-200 to the FACTORY SETTINGS (see p. 14). Connect the XRC-200 between your light controller and your light equipment.
Playing a sequence The light controller is not needed to play and can be disconnected. Enter the number of the sequence to play (from 1 to 64) and press the play button. Now the sequence is playing. It's possible to interrupt the sequence with the pause button. Press play to resume. Main Screen DMX in Status Aux Port...
Page 9
Menu The menu may be accessed by pressing the OK button, when the XRC-200 is stopped. The up and the down arrow keys are used to highlight menu items. The OK button is used to enter a highlighted submenu. Any setting changes but the time of the day and the day of the week are applied only when you return to the main screen.
Page 10
SEQUENCE 01 SEQUENCE 64 SET PARK SEQUENCE NONE SEQUENCE 01 SEQUENCE 64 DMX REMOTE CONTROL DMX FADE IN TIME SEQUENCES INFO EXTERNAL CONTACTS SYSTEM SETTINGS TIME DAY OF THE WEEK USER ACCESS LEVEL SET USER ACCESS LEVEL FULL ACCESS PLAYBACK ONLY KEYPAD LOCKED KEYPAD LOCKED STANDBY KEYPAD LOCKED STANDBY...
Page 11
NORMAL and FAST ACCESS. NORMAL mode When the XRC-200 is started in NORMAL mode, the user may select sequences or playlists by entering a sequence or a playlist number using the number keys. Selected sequences or playlists may be replayed using the play key.
Page 12
OK button. Note: The STARTUP TIMER will cause the XRC- 200 to start up only, if the XRC-200 has been in the STANDBY mode when the built in clock reaches the time configured and if the STARTUP TIMER has been configured.
Page 13
This dialog enables the configuration of the remote controllability via DMX of the XRC-200. The arrow buttons are used to select one of the 6 fields. When the dialog is opened, the field in the top left is selected. Press the OK button to enable or disable DMX REMOTE FAST ACCESS.
Page 14
OK button twice. EXTERNAL CONTACTS External contacts can only be used with the Swisson XRC-CT15b. The EXTERNAL CONTACTS are configured the same way as the FAST ACCESS CONFIG (see OPERATING MODES>FAST ACCESS CONFIG). However, for EXTERNAL CONTACTS, STOP and PAUSE are available as additional actions.
Causes the playlist to be halted until the contact, which is specified by the second parameter is triggered UNTIL TIME Halts the playlist until the XRC-200's clock reaches the time of the day specified by the second parameter FOR PLAY PRESSED...
Page 16
External Contact 01 has been triggered, the playlist will be continued on line 3, which will cause the XRC-200 to replay the sequence 5 twice. Then it will repeatedly replay the sequence 7 until the Contact 2 is triggered.
Technical Data Mains Voltage 100 - 240 [VAC] Main Frequency 50/60 [Hz] Fuse Delay-action fuse, 2 A, 250V Current Consuption Single Units 0.2 [A] Operating Temperature 0F to 131F (-17 C to 55 C) ° ° Protocol Standard ANSI E1.11 (DMX-512) Safety Standards EN60950-1 EMC emmision...