THE XENON BULB is highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer's operat i ng instructions. The bulb is stable at room temperature, but may still explode if
dropped or otherwise mishandled.
REFER bulb replacement and service to QUALIFIED PERSONNEL with adequate protec-
tive clothing (face shield, clean cotton gloves, welder's jacket). For routine lamphouse service, observe the
following rules:
1.
Allow the bulb to cool to room temperature before opening the lamphouse. Put on protective clothing
described above.
2.
De-energize the xenon power supply at the AC source before opening the lamphouse compartment.
3.
When possible, encase the bulb in its protective cover when cleaning or servicing the lamphouse
interior. The bulb, when outside the lamphouse, must be encased in the cover.
4.
Clean the bulb after it has cooled to room temperature. Do not touch the quartz envelope of the bulb;
fingerprints will burn in and create hot spots which may shorten bulb life. If fingermarks are made,
they should be care f ully removed with methyl alcohol and cotton prior to bulb operation.
5.
Never view an ignited bulb directly. BLINDNESS OR PERMANENT EYE DAMAGE MAY BE
INCURRED.
6.
Use only xenon bulbs designated as OZONE FREE. When possible, vent the lamphouse exhaust to
outside atmosphere.
7.
Maintain the lamphouse blower in good operating condition. Keep the blower inlet clean for unre-
stricted air flow.
8.
To insure maximum bulb life, operate the lamphouse blower and the exhaust system for at least ten
minutes after extinguishing the bulb.
9.
If returning a bulb for warranty adjustment, pack it in its original shipping container. Complete and
return all required warranty information.
10.
Dispose of expired bulbs that are beyond warranty in the following manner: Wrap the bulb tightly
in several layers of canvas or heavy cloth. Place it on a hard surface and shatter the envelope with a
sharp hammer blow. DO NOT place an unshattered bulb in an ordinary refuse container.
11.
DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE
OF XENON BULB HANDLING OR SERVICE.
Anode Pin
Seal

SAFETY PROCEDURES

Anode End Cap
Envelope
Anode
XST/004
Cathode End Cap
Seal
Cathode
Trigger Wire Cathode Pin