This manual should be kept for future reference. If you have any questions regarding your water conditioner, contact your local dealer or WaterCare at the following: 1900 Prospect Court • Appleton, WI 54914...
PREINSTALLATION INSTRUCTIONS FOR DEALERS: The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time. The dealer should read this page and guide the installer regarding hardness, day override, time of regeneration, service alarm and buzzer alarm settings before installation.
BYPASS VALVE: The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building.
INSTALLATION: GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere.
Page 6
7. INSTALLING GROUND: To maintain an electrical ground in metal plumbing of a home’s cold water piping (such as a copper plumbing system), install a ground clamp or jumper wiring. NOTE: If replacing an existing softener, also replace the ground clamps/wire. If removing a softener, replace the piping with the same type of piping as the original to assure plumbing integrity and grounding.
PROGRAMMING PROCEDURES: 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. STEP 1 –...
Page 8
STEP 5 – REGENERATION MINUTES: Set the minutes using + or — buttons. Press to exit installer programming. Press if you need to NEXT REGEN return to the previous step. To initiate an immediate manual regeneration, press and hold the button for three seconds.
OPERATING DISPLAYS AND INSTRUCTIONS: 1. GENERAL OPERATION: When the system is operating, one of three displays GENERAL OPERATION DISPLAYS may be shown. Pressing will alternate between the displays. One of NEXT the displays is always the current time of day. The second display shows the current treated water flow rate through the system in Gallons Per Minute.
Page 10
5. ERROR MESSAGE: If the word “ERROR” and a number are alternately ERROR flashing on the display record the number and contact the dealer for help. This indicates that the control valve was not able to function properly. 6. BRINE TANK MAINTENANCE AND SALT: Refill the brine tank as necessary, making sure at least 1/3 of the brine tank is full at all times.
START-UP INSTRUCTIONS: FLUSHING OF SYSTEM: To flush the system of any debris and air after installation is complete, please perform the following steps: 1. Rotate bypass handles to the bypass mode (see Fig. 2 of page 4). 2. Turn on inlet water and check for leaks in the newly installed plumbing. 3.
Page 12
8. SANITIZING OF UNIT UPON INSTALLATION AND AFTER SERVICE: At this time, it is advised to sanitize the softener: 1. Open brine tank and remove brine well cover. 2. Pour 1 oz. of household bleach into the softener brine well. 3.
TROUBLESHOOTING GUIDE: PROBLEM CAUSE CORRECTION A. No power at electric outlet A. Repair outlet or use working outlet B. Control valve power adapter not plugged into B. Plug power adapter into outlet or connect outlet or power cord end not connected to PC power cord end to PC board connection board connection 1.
Page 14
TROUBLESHOOTING GUIDE cont’d: PROBLEM CAUSE CORRECTION A. Turn bypass handles to place bypass in A. Bypass valve in bypass position service position 7. Control valve does not B. Meter is not connected to meter connection on B. Connect meter to three pin connection labeled regenerate automatically PC board METER on PC board...
Page 15
PROBLEM CAUSE CORRECTION A. Injector is plugged A. Remove injector and clean or replace B. Faulty regenerant piston B. Replace regenerant piston C. Regenerant line connection leak C. Inspect regenerant line for air leak 12. Control valve fails to D. Drain line restriction or debris cause excess D.
Page 16
TROUBLESHOOTING GUIDE cont’d: PROBLEM CAUSE CORRECTION A. Check motor connections then Press NEXT and REGEN buttons for 3 seconds to resynchronize A. Motor failure during a regeneration software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect.
Page 22
REPLACEMENT PARTS: WATER METER & METER PLUG Item No. Part No. Description Qty. CV3151 Nut, 1” QC CV3003 Meter assembly, includes items 3 & 4 CV3118-01 Turbine assembly CV3105 O-ring 215 CV3003-01 Meter plug assembly CV3013 Optional mixing valve SERVICE WRENCH - CV3193-02 Although no tools are necessary to assemble or disassemble the valve, the Service Wrench, (shown in various positions on the valve) is...
Page 23
REPLACEMENT PARTS: BRINE TANK ASSEMBLY Item No. Part No. Description Qty. CG2191-76 Brine tank cover, injection molded WC CG2180 Brine tank cover, standard CH1095-01 Optional 18” diameter salt grid CH1080 Optional 24” diameter salt grid CG21833CB1C00 18” x 33” brine tank, black CG21840CB1C00 18”...
Water-Right ® proudly warrants our WaterCare water conditioners to the original owner, at original installation location, when installed in accordance with Water-Right specifi cations from the date of original installation as follows:...