Triton T550i Installation And Operating Instructions Manual

Power shower pump

Advertisement

T550i
power shower pump
Installation and
operating instructions
I
nstallers please note these InstructIons are to be left wIth the user
2180149I February 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T550i and is the answer not in the manual?

Questions and answers

Summary of Contents for Triton T550i

  • Page 1 T550i power shower pump Installation and operating instructions nstallers please note these InstructIons are to be left wIth the user 2180149I February 2009...
  • Page 2: Table Of Contents

    Commissioning ..........9 Spare parts ..........11 Fault finding ..........12 Guarantee, Service Policy, Etc....Rear cover To check the product suitability for commercial and multiple installations, please contact Triton’s specification advisory service before installation. Telephone: 0844 980 0730...
  • Page 3: Plumbing And Electrical Notes

    MUST be fitted on the hot and cold water supplies to the pump as an independent means of isolating the water supplies should maintenance or servicing Replacement parts can be ordered from Triton be necessary. Customer Service. See ‘spare parts’ for details.
  • Page 4: Introduction

    SAFETY WARNINGS This book contains all the necessary fitting a. Under no circumstances must this pump and operating instructions for your Triton twin be connected to a mains cold water impeller power shower pump. Please read them supply. Failure to comply will invalidate the carefully.
  • Page 5: Key To Main Components

    T550i KEY TO MAIN COMPONENTS Fig.1 Pump (fig.1) 1 Inlet connector hose 2 Outlet connector hose 3 Integral flow switch 4 Variable speed control 5 PCB cover...
  • Page 6: Water Requirements

    (both In situations where this requirement cannot be fused at 3A) met, contact Triton Customer Service for advice. If used with a combination cylinder, the cold Ring main water cistern must have a capacity of at least...
  • Page 7: Electrical Requirements

    T550i ELECTRICAL REQUIREMENTS SITING OF THE PUMP WARNING! WARNING! THE UNIT MUST NOT BE POSITIONED THE PUMP MUST BE EARTHED. WHERE IT WILL BE SUBJECT TO FREEZING CONDITIONS. The pump must be connected to a 230 – 240V A.C. electrical supply, via a double pole switch The pump MUST ALWAYS be positioned with at least 3mm contact separation.
  • Page 8: Installation

    T550i INSTALLATION Before commencing installation of the pump, ensure the site conditions have been complied with fully. Also note the following: • Pipework to precede wiring. • The pump must be positioned in a dry area, ideally in the linen/airing cupboard. It must be...
  • Page 9 T550i Note: The pump MUST ONLY be placed in the Fig.5 horizontal position. c Connect the inlet flexible connectors to the inlet ports of the pump ensuring the filters are in position on the inlet sides (fig.4). The hot and cold supplies can be connected to either end of the pump.
  • Page 10 T550i IMPORTANT: Remove only the minimum Fig.7 amount of conductor insulation when wiring to the terminal block. The cable clamp must be used to secure the cable (fig.7). Earth post Note: Before replacing the cover, ensure the potentiometer is rotated fully clockwise (fig.8) until a ‘stop’...
  • Page 11: Variable Speed Control

    T550i VARIABLE SPEED CONTROL Fig.10 The variable speed control (fig.11) can be adjusted to select the optimum performance of the pump to suit personal preferences. COMMISSIONING Before the first operation of the shower pump, it is necessary to flush out any system debris from the installation.
  • Page 12 T550i 15 Switch off the electric supply to the pump and eliminate any leaks. Note: If care has been taken to prevent any obvious debris entering the system, the above procedure should be adequate for normal operating conditions of the pump and shower. However, it may be advisable to also clean the filters in the inlet ports of the pump as an extra precaution.
  • Page 13: Spare Parts

    T550i SPARE PARTS Description Part No. Pump assembly T550i00M Cover 7052286 Impeller housing 7051544 Pump inlet 7051543 Speed control knob 7051552 End cap 7052310 PCB assembly 7072314 Flow switch assembly 82300700 Flexible connector 22004500 inlet c/w filter Flexible connector 22004510...
  • Page 14: Fault Finding

    1.5 Faulty flow switch. 1.5.1 Replace switch. Contact Triton Customer Service for advice. 1.6 Failed pump motor. 1.6.1 Replace the pump unit. Contact Triton Customer Service. 2 Poor or no 2.1 Pump motor not 2.1.1 See causes 1.1, 1.2, 1.3, 1.4, 1.5, and 1.6 water flow.
  • Page 15 T550i...
  • Page 16 Fax: 0844 980 0744 Nuneaton Warwickshire CV11 4NR www.tritonshowers.co.uk Triton is a division of Norcros Group (Holdings) Limited E-mail: serviceenquiries@tritonshowers.co.uk 4-12-2012 - 1 yr mix TRITON reserve the right to change product specification without prior notice. E&OE. © TRITON SHOWERS 2013...