C.4.2 Testing Data
Electrical Characteristics
NO
ITEM
Complete
1
Charge
Nominal
2
Capacity
3
Cycle Life
4
Storage
Environmental Characteristic
NO
ITEM
Temperature
1
testing
Constant
2
temperature
/humidity
3
Vibration
Impacting
4
Testing
5
Free fall
Safe Characteristic
NO
ITEM
1
Short Circuit
Over charge
2
testing
Over
3
discharge
testing
C.4.3 Cautions
1) The best operating performance is between -20 ~ +60 °C. Higher or lower temperature could cause
damage to the battery.
2) Operated with external power supply will not hurt battery life since battery does not discharge. Therefore, it
operating temperature range is -40 ~ +85°C.
3) Recharge the battery for 10 hours before use.
Rikaline
International Corp.
Tel: ++886 2 2370 4688
Bluetooth GPS
Within 3 months
Within 1 year
TESTING INSTRUCTION
Charge the battery with 1c of constant current and 4.2V
constant voltage for 2.5 hours.
Measure discharge capacity with discharge current 0.2C to 2.75V
cut-off within 1 hour after complete charge.
Measure the capacity after 300 cycles of complete charge
and discharge at 1C current to 2.75V cut-off
Capacity after 30days storage at 25
charge
Capacity after 7days storage at 60
TESTING INSTRUCTION
Measure capacity with constant discharge current 1C to 2.75V
cut-off at each temperature after complete charge at 25 .
Percentage as an index of the capacity compared with
100% at 25 .
Keep the battery at 40
The battery will be vibrated 10 times in three mutually
perpendicular directions with amplitude of 0.35mm and
changing frequency between 10 and 55Hz. The rate of
scanning frequency is from 10Hz to 55Hz with the rate of
1Hz per min.
The battery will be impacted 1000±10 times with the
acceleration of 100m/s
The battery will be dropped free five times in three mutually
perpendicular directions from the height of 1.0m onto a
hard board with the thickness of 20mm
TESTING INSTRUCTION
The battery is to be short-circuited by connecting the
positive and negative terminals of the battery with and
external load of less than 50
According to the method of UL
After complete charge, the battery will be discharged to end
voltage. Then Connect with external load of 30
10F, 64, Kang-Ding Road, Taipei 108, Taiwan
Fax: ++886 2 2370 4686
GPS-6033 Operating Manual
-20~+45 °C*
-20~+25 °C*
from complete
ffom complete charge
and 90%RH for 96hrs
2
and pulse lasting time 16ms.
m
E-Mail: info@rikaline.com.tw
Rikaline
REQUIREMENTS
950mAh
80% of initial Capacity
Retention capacit
Recovery capacity
REQUIREMENTS
25% at -20
60% at 0
100% at 25
96% at 60
Recovery capacity
The
battery
rupture, smoke, catch fire,
vent or leak.
REQUIREMENTS
The
battery
rupture, smoke, catch fire,
vent or leak.
for 24hrs.
Web: www.rikaline.com.tw
y 90%
90%
85%
shall
not
shall
not
18