Usb Storage Information Registration - Sanyo VPC-S5 Service Manual

Hide thumbs Also See for VPC-S5:
Table of Contents

Advertisement

3-9. Firmware uploading procedure
1. Uploading the firmware should be carried out if the version
number (COMPL PWB XX-X) on the replacement circuit
board is lower than the version of the distributed firmware.
For XX-X, enter the name of the circuit board containing the
firmware.
2. The firmware is distributed by e-mail in self-extracting archive
format. Change the extension of the distributed file to .EXE
and save it in your proferred folder.
3. When you double-click the saved file, the firmware (binary
file) will be saved in the same folder.
4. The firmware must not be distributed without permission.
1. Overwriting firmware from the SD card
Preparation:
SD card: SD card with firmware rewritten into the root direc-
tory
Data: S71BNxxx.BIN (xxx: version)
Overwriting method:
1. Insert the above SD card.
2. Set the main switch to PLAY.
3. Turn on the camera.
4. Press the MENU button. The playback option screen ap-
pears.
5. Choose the OPTION icon.
6. Choose the FORMAT.
7. Press the left key for 2 seconds. FIRMWARE UPDATE will
display.
8. Choose YES.
9. Press the SET button. Update is starting.
Note:
Do not turn off the camera's power or remove the SD card
while the firmware is being updated.
The power will turn on automatically after the update is com-
plete.
2. Overwriting firmware from USB
Preparation:
PC with overwriting firmware copied to the preferred folder in
the HD.
Data: S71BNxxx.BIN (xxx: version)
Overwriting method:
1. Connect the camera to the computer with USB cable, and
turn on the camera.
2. Check that the camera is fully connected to the computer.
3. Double-click on the DscCalDi.exe.
4. Click the Firmware.
5. Choose the fimware file to use for overwriting.
6. Click the Yes.
7. Update is starting. The message will appear, and choose
OK.
8. After the update is complete, disconnect the USB cable
and turn the camera's power off.
Note:
Do not turn off the camera's power or remove the SD card or
end the calibration software while the firmware is being up-
dated.
4. USB STORAGE INFORMATION
REGISTRATION
USB storage data is important for when the camera is con-
nected to a computer via a USB connection.
If there are any errors in the USB storage data, or if it has not
been saved, the USB specification conditions will not be sat-
isfied, so always check and save the USB storage data.
Preparation:
POWER switch: ON
Adjustment method:
1. Connect the camera to a computer. (Refer to 3-5. Con-
necting the camera to the computer on the page 13.)
2. Double-click on the DscCalDi.exe.
3. Click on the Get button in the USB storage window and
check the USB storage data.
VID: SANYO
PID: S5
Serial:
Rev. : 1.00
4. Check the "Serial" in the above USB storage data. If the
displayed value is different from the serial number printed
on the base of the camera, enter the number on the base
of the camera. Then click the Set button.
5. Next, check VID, PID and Rev. entries in the USB storage
data. If any of them are different from the values in 3. above,
make the changes and then click the corresponding Set
button.
Calibration
Upload
AWB
Firmware
Focus
Image
UV Matrix
Cal Mode
Initialize
OK
EVF
Cal Data
LCD Type
OK
USB storage
VID
Get
PID
Set
– 17 –
LCD
R Bright
B Bright
RGB Offset
Gain
Tint
Phase
VCO
H AFC
Test
Set
Serial
Set
Set
Rev.
Set
VCOMDC
VCOMPP
Hall Cal.
Setting
Language
Video Mode
Factory Code

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vpc-s5uVpc-s5bk

Table of Contents