Mounting Preparation

Before the Outdoor Enclosure may be installed, the mounting surface must be
prepared and an access hole for wiring and the environmental seal created. The
Outdoor Enclosure and Roxtec Gland M63 seal should NOT be mounted at this time.
The Outdoor Enclosure shall be designed to mount directly to any solid surface
including a wall anchor, wood, sheet metal, or dry wall using screws with a thread
type no larger than 5/16". When mounting, only the mounting flanges will touch the
surface (i.e., the entire rear surface area of the enclosure will not touch the mounting
surface – there is a step of 0.05"). When mounting on drywall, please ensure that at
least one vertical pair of mounting holes is secured to a stud. A schematic has been
provided in Figure 1 which displays the rear-mounting surface of the enclosure and its
dimensions.
The rear of the Roxtec Gland M63 enclosure seal shall protrude past the enclosure
wall and into the wall approximately 42 mm. An access hole in the wall for the seal
and wiring must be created. This access hole must be slightly larger than the size of
the Roxtec Gland M63 seal which is 73 mm in diameter.
The Veri-Series fingerprint reader and Outdoor Enclosure should be mounted on the
wall or structure to be in compliance with all American Disabilities Act (ADA), local
and federal laws as they apply to the installation. The reader should also be mounted
at a height that is comfortable to use. In general, the fingerprint reader should be
mounted such that the height of the sensor (top of the device) is between 48 and 54
inches from the ground.
Document# 430-00146-01
© Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.