  • Page 1 V-ENC Enclosure Installation Guide Veri-Series Outdoor Enclosure (Models VENC, VTENC, VNENC) March 23, 2005 Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 2 Page 1 Introduction The Bioscrypt Veri-Series fingerprint readers are manufactured for indoor use, and if placed outdoors must be installed within a complete Bioscrypt certified enclosure to protect the reader against direct contact with the elements, including rain, sun, snow, or excessive moisture. Failure to place any reader installed outdoors within such an enclosure shall void the warranty on the fingerprint reader.
  • Page 3 Bioscrypt accepts no liability for the misuse of third-party hardware mentioned in this document. In no case shall Bioscrypt be liable for damage to a reader resulting from the misuse of such hardware. No part of this publication may be placed in a retrieval system, transmitted, or...
  • Page 4 Tampering, such as opening the housing of a biometric reader or replacing parts will void this warranty. The warranty is void if the serial number of the Bioscrypt product has been defaced, altered, or removed or if the product has been modified.
  • Page 5 The newest Bioscrypt Veri-Series products are designed to be weather resistant but no sensor technology exists today that can work in all weather environments. If a...
  • Page 6 50° C to 150° C (-58° F to 302° F) and momentary temperatures to 200° C (392° F). Overall, the Bioscrypt Veri-Series Outdoor Enclosure shall measure 11.31” x 9.31” x 5.43” (287 x 236 x 138 mm). The Enclosure shall be comprised of:...
  • Page 7 Lid Option: Window lid should be selected for readers installed in shaded areas. Solid lid should be selected for readers installed in direct sun. Heater Option: Should be selected for readers installed in near or below-freezing environments. Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 8: Mounting Preparation

    In general, the fingerprint reader should be mounted such that the height of the sensor (top of the device) is between 48 and 54 inches from the ground. Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 9 Within the Outdoor Enclosure, fasten gland housing with the lock nut. Pull all the required cables through the gland housing and into the Outdoor Enclosure.* Please refer to the Veri-Series Setup Guide and Veri-Series Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 10 12 to 36 V AC/DC. However, a power supply rated at either 12 VDC / 7.0 A or 24 VDC / 3.5 A is recommended. It is recommended that this power supply Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 11 Sub Panel access hole) and use them to secure the Veri-Series Wall Mount to the Sub Panel. Create the connections from the cables to the Veri-Series reader and Sub Panel: o 15-Conductor Pigtail (for use with V-Prox, V-Flex, V-Pass and V-Smart) Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 12 A schematic has been provided in Figure 3 which displays the assembly of the Roxtec Gland M63 seal and Sub Panel. Figure 3: Roxtec Gland & Sub Panel Assembly Mounting the Outdoor Enclosure Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 13 The Veri-Series fingerprint reader is now ready for use outdoors. When a user needs to access the reader, simply lift the front lid and initialize the verification. Once the verification is complete the lid may be closed once more. The Outdoor Enclosure Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 14 NEMA ratings. It is NOT necessary to engage the bottom latch after every use for installations that do not require NEMA certified rating. The latch may be optionally secured with a padlock. Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
  • Page 15 High Wycombe, Buckinghamshire 905 624 7700 818 304 7150 England HP15 7TZ 905 624 7742 818 461-0843 +44 (0) 1494 814 404 www.bioscrypt.com +44 (0) 1494 815 513 Document# 430-00146-01 © Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.