CLEARANCES TO COMBUSTIBLES

INSTALL ALL VENTS AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER!
When your Pellet Stove Room Heater is being installed on a combustible fl oor it is mandatory that a 1/2" (13mm) thick non-
combustible hearth pad be installed under the heater. The non-combustible hearth pad must extend at least 6" beyond the
fuel loading and ash removal openings and at least the depth of the heater plus 6 inches (152mm) out in front of the heater.
This applies to both freestanding heaters and insert heaters.
BACK WALL
6"
USA 6"
CANADA 18"
Figure 6
2"
USA 6"
CANADA 8"
FLOOR PROTECTION
Alcove Dimensions
40"
2"
FLOOR
PROTECTION
USA 6"
CANADA 8"
USA 6"
CANADA 18"
36"
35"
11
Figure 5