TMP86CM47U-3RD2 (DS: IC151)
TMP86CM47U-3RD2 Terminal Function
Pin
Pin Name
No.
1
VSS
2
XIN
3
XOUT
4
TEST
5
VDD
6
P21(LED)
7
P22
8
RESET_
9
P20
10
P00(INT0)
11
P01
12
P02
13
P03
14
P04(SO)
15
P05(SI)
16
P06(SCK_)
17
P07(INT4/LED)
18
P17
19
P16
20
P15
21
P14
22
P13
23
P12(INT2)
24
P11(INT1)
25
P10
26
P30
27
P31
28
P32
29
P33
30
P34
31
P35
32
P36
33
P37
34
VAREF
35
AVDD
36
AVSS
37
P40
38
P41
39
P42
40
P43
41
P44
42
P45
43
P46
44
P47
* Pd or Pu detected in input port when power on, Pd=CD1, Pu=CD2
33
34
44
1
Symbol
I/O
DET
VSS
—
—
XIN
I
—
XOUT
O
—
TEST
I
—
VDD
—
—
DVSEL
O
—
BREQ1_
O
—
RST_
I
—
DRLCH
O
—
MCMD_
I
—
DMA
O
—
DMABSY1
I
—
ATANS
O
—
ATDATA
O
—
MDATA
I
—
MCLK
I
—
BSYIN_
I
—
BSYOUT_
O
—
DRES_
O
—
DMAR_/W
I/O
—
RD_
O
—
WR_
O
—
INTRQ
I
Lv
DMARQ
I
Lv
IORDY
I
—
D0
I/O
—
D1
I/O
—
D2
I/O
—
D3
I/O
—
D4
I/O
—
D5
I/O
—
D6
I/O
—
D7
I/O
—
VAREF
I
—
AVDD
I
—
AVSS
I
—
D8
I/O
—
D9
I/O
—
D10
I/O
—
D11
I/O
—
D12
I/O
—
D13
I/O
—
D14
I/O
—
D15
I/O
—
23
22
TOP VIEW
12
11
Ext
Ini
Res
—
—
—
GND (0V)
—
—
—
Oscillation input 8.0MHz
—
—
—
Oscillation output
—
—
—
Fixed to L
—
—
—
Power (+3.3V)
Pu
L
H
Not used
System µcom bus request
Pu
H
H
µcom reset
—
—
—
Pu
H
H
ATAPI data register latch signal, H: Latch
System µcom serial interface
—
—
—
Pu
L
H
ATAPI DMA mode select (H: DMA)
Pu
—
H
In DMA flag (L: DMA data transfer)
System µcom serial interface
Pu
H
H
System µcom serial data receive signal
Pu
H
H
System µcom serial data send signal
—
—
—
System µcom serial send/receive clock
—
—
—
—
—
H
TXD BUSY input
Pu
H
H
TXD BUSY output signal (L: BUSY)
Pd
L
L
DSP reset (L: Reset)
Pu/Pd
H
L/H
ATAPI DMA direction select (L: Read) *
—
H
—
ATAPI read strobe
—
H
—
ATAPI write strobe
—
—
—
ATAPI interrupt request signal
Pd
—
—
ATAPI DMA request signal (Pd with 5.6kW)
Pu
—
H
ATAPI data transfer cycle extend request signal (Pu with 1.0kW)
Pd
L
L
ATAPI data bus 0 (APRES_ATAPI reset)
—
—
—
ATAPI data bus 1 (CS1 device register chip select 1)
—
—
—
ATAPI data bus 2 (CS0 device register chip select 0)
—
—
—
ATAPI data bus 3 (DA2 device register select 2)
—
—
—
ATAPI data bus 4 (DA1 device register select 1)
—
—
—
ATAPI data bus 5 (DA0 device register select 0)
—
—
—
ATAPI data bus 6
—
—
—
ATAPI data bus 7
—
—
—
GND (0V), Analog ref. V for A/D conversion, A/D not used
—
—
—
Power (+3.3V), Power for A/D conversion circuit only
—
—
—
GND (0V), Analog GND for A/D conversion
—
—
—
ATAPI data bus 8
—
—
—
ATAPI data bus 9
—
—
—
ATAPI data bus 10
—
—
—
ATAPI data bus 11
—
—
—
ATAPI data bus 12
—
—
—
ATAPI data bus 13
—
—
—
ATAPI data bus 14
—
—
—
ATAPI data bus 15
27
DN-S3000
Function
27