Download Print this page

Denon DN-S3000 Service Manual page 10

Table top single cd player
Hide thumbs Also See for DN-S3000:

Advertisement

Detailed error can be displayed by PLATTER when error occurs.
Error Indication
TR
MIN
SEC
Displays the track
Displays the time at which error occurred.
No. in which error
occurred.
5. System µcom and DSP Version Upgrade
System µcom and DSP can be upgraded in the following manner.
Version Upgrade Method
(1) Record the version upgrade software on a CD-R or CD-RW disc, only as one file with the format ISO9660 Mode-1.
The file name of the supplied version upgrade software should be used as is and this disc needs to finalize.
(2) After loading the disc made in above step 1, turn off the power. Then, turn on the power while pressing the NEXT TRACK
button and FAST SEARCH FWD (
) button. The version upgrade starts with reading data of the disc.
(3) When you start version upgrade operation, messages "Version_Up" and "System&DSP" are displayed on the character dis-
play.
Recovery positions are turned on one by one from the left end according as the upgrade operation proceeds. When this op-
eration is completed, all recovery positions are turned on.
In case of some error or the power is turned off during the version upgrade, it may be impossible to operate at all thereafter.
Changing of IC502 on GU-3546 is necessary in this case, and software writing to IC502 should be done beforehand.
(4) When the upgrade is completed, the disk is ejected and operation returns to the normal mode.
(5) File name of the upgrade software indicates version numbers.
File name
T3. * * *
* * * . BIN
System com
DSP version
version
6. ROM Drive (FG-5000) µcom Version Upgrade
Drive (FG-5000) µcom can be upgraded in the following manner.
Version Upgrade Method
(1) Record the version upgrade software on a CD-R or CD-RW disc, only as one file with the format ISO9660 Mode-1.
The file name of the supplied version upgrade software should be used as is and this disc needs to finalize.
(2) After turning on the power, load the disc made in above step 1 into the mecha. you want to upgrade the version.
(3) "Drive" and "Version UP?" are indicated in the character display. Press the CD EJECT button and remove the disc when not
upgrade the version.
(4) Press the PLAY/PAUSE to start the version upgrade. "Now Loading" is indicated.
(5) When the version upgrade is finished, "Complete" is indicated and the disc EJECT.
(6) Turn off the power once and turn on again after take out the disc.
The version upgrade ends in 20~30 seconds normally. If the power turned off underway or the version upgrade ends
abnormally, the drive may become malfunction. In such a case, version upgrade with PC will be needed.
(7) File name of the upgrade software indicates version number.
File name
FG5K * * * * . BIN
Version number
FRAM
CHARACTER
"H * * * *
E * * * "
Operation count
Error code
10
DN-S3000
10

Hide quick links:

Advertisement

loading