Technical Data; High Altitude Installation - Rinnai ES38 RHFE-1004RFA Conversion Manual

Rinnai es38 energysaver gas direct vent wall furnace
Hide thumbs Also See for ES38 RHFE-1004RFA:
Table of Contents

Advertisement

Available languages

Available languages

Minimum supply gas pressure
Maximum supply gas pressure
BTU/hour input
BTU/hour output
Code
A1
0-2000 ft
Altitude
0-610 m
Manifold test
1.97 in
pressure -
(50
mm
W.C. Low
Manifold test
3.7 in
pressure -
(94
mm
W.C. High
Burner Orifice - High
Burner Orifice - Low
Damper Adjustment
The input rate can be verified by following the procedure in the National Fuel Gas Code (NFPA54 / ANSI Z223.1,
2006 or latest edition).
Conversion of the appliance for operation at high altitudes (> 2000 ft, 610 m) requires the completion of the
section, Adjust Gas Pressure Settings, using the high altitude manifold test pressures above. No parts need to be
replaced for high altitude.
For high altitude installations in Canada, the conversion shall be carried out by a manufacturer's authorized
representative, in accordance with the requirements of the manufacturer, provincial or territorial authorities having
jurisdiction and in accordance with the requirements of CAN/CGA-B149.1 or CAN/CGA-B149 installation codes.
2

Technical Data

Natural Gas
A2
A3
2001-5200 ft
5201-7700 ft
611-1585 m
1586-2347 m
1.97 in
1.97 in
)
(50
)
(50
mm
mm
3.3 in
3.0 in
)
(83
)
(76
mm
mm

High Altitude Installation

Rinnai Corporation ES38 Conversion Manual
Natural Gas
5.0 in (127 mm) W.C.
10.5 in (267 mm) W.C.
Low 10,500
High 38,400
Low 8,400
High 30,720
A4
L1
7701-10200 ft
0-2000 ft
2348-3109 m
0-610 m
1.97 in
4.29 in
)
(50
)
(109
mm
mm
2.8 in
10.1 in
)
(70 mm)
(257
mm
Natural Gas
1004F-2031-B-1.80
0.071 in (1.80 mm)
1004F-2036-B-1.95
0.077 in (1.95 mm)
Front
Right
7/10
10/10
Propane Gas
11.0 in (280 mm) W.C.
13.0 in (330 mm) W.C.
Low 10,500
High 36,500
Low 8,400
High 29,200
Propane Gas
L2
L3
2001-5200 ft
5201-7700 ft
611-1585 m
1586-2347 m
4.29 in
4.29 in
)
(109
)
(109
mm
mm
9.1 in
8.3 in
)
(232
)
(212
mm
mm
Propane Gas
1004F-2031-A-0.95
0.037 in (0.95 mm)
1004F-2036-A-1.20
0.047 in (1.20 mm)
Left
Front
Right
10/10
10/10
10/10
L4
7701-10200 ft
2348-3109 m
4.29 in
)
(109
)
mm
7.6 in
)
(194
)
mm
Left
10/10

Hide quick links: