Explanation
SW No.
settingitems
SettingNo.
Contents
Fact.set
03
Transmission start
speed
00
01
02
03
2400 BPS
4800 BPS
7200 BPS
9600 BPS
This is to set the training start speed of the
MODEM.
It is recommended that if Tx. error occurs
frequently set to 4800BPS.
This is to set the condition of transmitting TSI.
75
76
L
00
01
02
None
Transmit in
TSI
01
00
anycase
Transmit only
when CSI
receives
Response to the
first DIS
77
78
DCS timing
00
01
This is to set the response of DCS corre-
sponding to DIS.
In order to consider the influence of the echo
while transmitting to overseas fax.
2nd DIS (SETTING No. 01) might be effective.
Response to the
second DIS
00
This is to set the interval between DCS and
training for the purpose of correcting
the
mismatching of between Sanyo and other
manufacture's machine.
OCITT recommendation is 75 + 20 ms.
Interval between DCS
and Training
00
01
02
00
01
02
75 msec.
0.3 sec.
0.5 sec.
75 ms
0.3 sec.
0.5 sec.
This is to set the interval between RTC and Q
for the purpose of correcting the mismatching
of between Sanyo and other manufacture's
machine.
OCITT recommendation is 75 + 20 ms.
This is to set the delay for correcting the
mismatching of between Sanyo and other
manufacture's machine.
79
81
Interval between RTC
and Q
00
FSK release delay
00
01
02
03
04
0 ms
100 ms
200 ms
300 ms
400 ms
02
This is to set the transmission level attenuation
for control and video signals.
00
I
15
0 dB
82
83
Transmission attenuator
I
15dB
10
04
DTMF attenuator
00
I
15
00
0 dB
This is to set the transmission level attenuation
for Dual Tone Modulated Frequency (DTMF)
dial.
I
15dB
An equalizer which adjust the characteristics
of the non-loaded
cable between fax and
exchange
station. Set in response to the
distance to the exchange.
Even when select Reception is set reception is
free from any Sanyo fax machines at On.
(SEl_HNG
No.
01).
In case of ON, SFX-30 precut the recording
paper along the fold for reception and copy.
84
Cable equalizer
OKm
01
02
03
00
01
L
1.8Km
3.6Km
5.6Km
OFF
ON
OFF
ON
k
88
93
E
Closed network
communication Free
pass Sanyo unit
Paper precut
k
00
01
* In case of fixing the overseas transmission mode, set to SW No. 71 to 01, SW No. 78 and 79 to 01 or 02
* The SW No. 60-– 93 are classified as follows.
60 and 61
: For testing purpose
66
: For checking the party's response
67-74
: Countermeasure
for the reception problem
75-81
: Countermeasure
for the transmission problem
82-84
: Countermeasure
for the problem caused by line characteristics
88 and 93 : Others
L