ACCESSORY PF06-YJLF-F
Tools required: Phillips screwdriver
NOTICE: Shut off gas heater during
the following blower installation.
1.
Remove the knock-out center
panel from back of heater with
a Phillips head screwdriver (see
Figure12-F).
2.
Disconnect power cord wires
from blower motor (if connected)
(see Figure 13-F).
3.
Disconnect green ground wire
f r o m
b l o w e r
connected) by removing screw
holding
wire terminal (see
Figure 13-F).
4.
Install one plastic bushing
provided in blower kit into the
"
1.5
hole in the left rear of firebox
floor. Access hole through the
rectangular opening in the rear
panel (see Figure 14-F).
5.
Attach
the
two
brackets to blower housing
using four screws provided in
blower kit ( 2 for each bracket)
(see Figure 15-F).Tighten screws
securely. Place blower assem-
bly temporarily on top panel.
6.
Working from the rear of
thestove, place entire power
cord, including operation control
housing in the lower control
Figure 12-F-Removing
Stove Knock-out Panel
Blower Accessory Model
compartment.
7.
Route ends of
cord up from the lower control
compartment through the plastic
bushing, then up to the upper
cavity of stove (see Figure 16-F).
8.
Using one big black screw
provided in blower kit, mount
bracket with thermostat switch
to the left of firebox on back of
heater. (see Figure 16-F).
9.
Attach the terminal ends of the
white and black power cord
wires to the terminals on the
blower motor (see Figure 13-F)
Push firmly.
h o u s i n g ( i f
10. Attach the terminal end of the
green power cord wire to the
front tab of the blower housing
using the screw provided (see Fig-
ure 13-F).
11. P l a c e
temporarily on top panel.
12. Place operation control housing
just inside
door in front of stove (see Figure
mounting
15-F).
13. Using two black screws pro-
vided in blower kit, mount blower
speed control housing to mount-
ing tab in left side of lower control
compartment (see Figure 15-F).
14. Check to make sure that the
power cord is completely clear
of blower wheel and there are
Figure 13-F-Removing Wires
From Blower
Figure 14-F -Installing Bushing
PF06-YJLF-F
4-wire power
b l o w e r
a s s e m b l y
control compartment
1 0
no foreign objects in blower
wheel.
15. Using the previously removed
screws, mount blower assembly
to stove by reattaching the knock-
out center panel to rear panel
(see Figure 15-F). Tighten screws
securely.
16 Use screws provided in blower kit
to assemble the plate which as-
sembled with strain relief bush-
ing and power cord on the knock-
out center panel.
17. Peel off the backing paper and
stick the supplied wiring diagram
decal on the stove floor as shown
in Figure 14-F.
18. Plug power cord into a conve-
nient 3-prong grounded wall re-
ceptacle near the stove.
19. Using Auto/O/Man switch, turn
blower on and check for operation.
Turn on Auto/O/Man switch to the
desired position. Man position will
remain constantly on. Auto posi-
tion will be controled by the
thermostat on fan blower unit.
To stop the operation turn until
switch to the O position.
19. All remaining parts from blower
kit may be discarded.
WARNING:
GROUNDING INSTRUCTIONS
This appliance is equipped with a
three-prong (grounding) plug for your
protection against shock hazard and
should be plugged directly into a
properly grounded three-prong
receptacle.
Figure 15-F -Attaching Brackets to
Blower and Mounting Blower
ELECTRICAL