Infinity high capacity continuous flow gas hot water system
Hide thumbs Also See for Infinity 32e:
Table of Contents

Advertisement

3a.Main Solenoid Valve (SV
3b.Solenoid Valve 1 (SV
3c. Solenoid Valve 2 (SV
Infinity REU-V3232W /HD250E REU-V3232WC
Infinity 32e and HD70e
) Circuit
0
) Circuit
1
) Circuit
2
Check the main solenoid if error indicator "11"
is displayed.
a.)
Disconnect Main Solenoid connector and
measure resistance between Pink and Black.
Normal: 1.5~1.9k
If normal, proceed to
Faulty: Replace Main Solenoid.
b.)
Measure voltage between Pink-Black of
Main Solenoid connector.
Normal: DC80~100V
If normal, proceed to Solenoid Valve SV
Faulty: Replace PCB.
Check Solenoid 1 if error indicator "11" is
displayed.
a.)
Disconnect Solenoid 1 connector and
measure resistance between Red and Black.
Normal: 1.8~2.2k
If normal, proceed to
Faulty: Replace Solenoid 1.
b.)
Measure voltage between Red and Black of
Solenoid 1 connector.
Normal: DC80~100V
If normal, proceed to Solenoid Valve 2
(SV
) Circuit
2
Faulty: Replace PCB.
a.)
Disconnect Solenoid Valve 2 connector and
measure resistance between Orange and
Black.
Normal: 1.8~2.2k
If normal,, proceed to
Faulty: Replace Solenoid Valve 2.
b.)
Measure voltage between Orange and Black
of Solenoid Valve connector.
Normal: DC80~100V
If normal, proceed to Thermal fuse Circuit.
Faulty: Replace PCB.
- 27 -
b
.
1
b
.
b
.
Issue 1 - 8/09/03 ©Rinnai