Product Description-PanelIR 4555
Controls
The model 4555 PanelIR heater is designed to be powered by one of the standard Research Inc. control panels. The model of the
control panel required depends on (1) the voltage and amperage required to power the panel, (2) the electrical service in the facility,
and (3) the type of temperature control required for the process.
The 900 series control panels are for single phase power and the 925 series panels are for three phase power. Both series can be
specified with circuit breakers from 20 amps to 80 amps and with manual or set point control.
Terminal blocks inside the panel allow convenient termination for incoming power, all lamps and the forced air blower. A step down
transformer is included in the 480 volt panel to power the 220 volt blowers.
Power Controller Chart for Model 4555 PanelIR
This chart shows the control panels that are available for all sizes of the Model 4555 PanelIR heater.
Heater Module
Model 4555-05-06
Model 4555-05-12
Model 4555-10-06
Model 4555-10-09
Model 4555-10-12
Model 4555-16-06
Model 4555-16-09
Model 4555-16-12
Model 4555-25-06
Model 4555-25-09
Model 4555-25-12
Model 4555-38-06
Model 4555-38-09
Model 4555-38-12
Research, Inc.
cont.
Power Controller
240 Volt 1 Phase
900-240-20
900-240-40
900-240-40
900-240-40
900-240-60
900-240-60
5
240 Volt 3 Phases
925-240-30
925-240-30
925-240-30
925-240-30
925-240-30
925-240-60
925-240-60
Product Description
480 Volt 3 Phase
925-480-30
N/A
925-480-30
925-480-30
925-480-30
925-480-60
925-480-30
925-480-60
925-480-80

Advertisement