Research StripIR 5306 User Manual

Infrared line heater

Advertisement

Quick Links

Model 5306 User's Manual
Publication #: A106837-001 Rev. 1
February 2003
Another quality product from:
7128 Shady Oak Road, Eden Prairie, MN 55344
Phone: (952)9499--9009 Fax: (952)949-9559
E-mail: sales@researchinc.com
www.researchinc.com

Advertisement

Table of Contents
loading

Summary of Contents for Research StripIR 5306

  • Page 1 Model 5306 User’s Manual Publication #: A106837-001 Rev. 1 February 2003 Another quality product from: 7128 Shady Oak Road, Eden Prairie, MN 55344 Phone: (952)9499--9009 Fax: (952)949-9559 E-mail: sales@researchinc.com www.researchinc.com...
  • Page 2: Table Of Contents

    Table of Contents Section 1 – Introduction..................1-1 Section 2 – Features & Benefits................2-1 Section 3 – Specifications..................3-1 Dimensions......................3-2 Ordering Information....................3-3 Accessories, Spare & Replacement Parts............... 3-3 Section 4 – Safety..................... 4-1 Section 5 – Installation…………………………………………….……………... 5-1 5.1 Un-pack and Check for Damage...............
  • Page 3: Section 1 - Introduction

    Section 1 – INTRODUCTION ® The Model 5306 StripIR Infrared line heater is designed for use in any application that requires a clean, responsive, non-contact heat source. Typical applications for the Model 5306 include: Drying paint Curing adhesive Drying ink Forming plastic Stress relieving metal Heat treating...
  • Page 4 Electrical Cable – The Model 5306 heater is electrically wired from the T3 lamp to intermediate terminal block within the heater. An 8-foot (2.4 m) electrical cable is supplied with each heater. Optional Quartz Window – A quartz window can be ordered along with each size of the Model 5306.
  • Page 5: Section 2 - Features & Benefits

    Section 2 – FEATURES & BENEFITS The design and functionality of the Model 5306 supplies a variety of features and related benefits: Rapid Response – The quartz halogen lamps heat up and cool down instantly in response to power control signals. They reach 90 percent of full operating temperature within three seconds of a cold start.
  • Page 6: Section 3 - Specifications

    Section 3 - SPECIFICATIONS Specification 5306-02 5306-05 5306-10 5306-16 5306-25 5306-38 Weight, Pounds (kg) 1.6 (0.60) 2.2 (0.82) 3.1 (1.2) 4.1 (1.5) 5.8 (2.2) 8.1 (3.0) QIH120- QIH240- QIH240- QIH240- QIH600- QIH480- Lamp Type 1000RI2 1000R12 2000R12 3000R12 5000R12 3800R12 Lamp Part Number 106587-001 103390-002 103390-004 103390-012 103390-008 103390-010...
  • Page 7: Dimensions

    Dimension Model Number Inches (mm) Inches (mm) Inches (mm) 5306-02 6 (152.4) 2.5 (63.5) 5.3 (133.4) 5306-05 9.5 (241.3) 6 (152.4) 8.8 (222.3) 5306-10 14.5 (368.3) 11 (279.4) 13.8 (349.3) 5306-16 20.1 (510.5) 16.6 (421.5) 19.4 (491.5) 5306-25 29.5 (749.3) 26 (660.4) 28.8 (730.3) 5306-38...
  • Page 8: Ordering Information

    Ordering Information – Model 5306 Model Product Description 5306 Infrared Strip Heater (Installed lamp included) Code Length Lighted Lamp Length Reflector Length Overall Heater Length 2 in (51 mm) 2.56 in (65 mm) 5.3 in (133 mm) 6 in (152 mm) 5 in (127 mm) 5 in (127 mm) 8.8 in (222 mm)
  • Page 9: Section 4 - Safety

    Section 4 – SAFETY GENERAL: The Model 5306 heater is designed for safe operation. Nevertheless, installation, maintenance, and operation of the heater can be dangerous for a careless operator or maintenance person. For your safety and the safety of others, read the instructions in this Instruction Manual and follow these safety practices to help prevent accident or injury.
  • Page 10 FIRE SAFETY: Obey the same fire-safety rules you observe when working with hot plates, propane or acetylene torches, soldering irons, and other equipment that operates at extremely high heat. Remove all solids, liquids, and gases that burn easily from the area around the heater.
  • Page 11: Section 5 - Installation

    (see Figure 3-2). Note: Vertical burn lamps are recommended when operating the Model 5306 in a vertical orientation. All Research Inc. lamps associated with the Model 5306 heater are designed for vertical operation, except for the lamps used in the 5306-02.
  • Page 12: Heater Cooling Connections

    HEATER COOLING CONNECTIONS: Each Model 5306 is designed with two ‘quick-disconnect’ fittings protruding from the top of the heater cover. The fittings located at the outer ends of the heater are the inlet/outlet cooling water ports. Both fittings accept 1/4-inch outer-diameter flexible nylon tubing. A 20-ft. (6 m) length of tubing and two additional quick-disconnect fittings are shipped with each Model 5306 heater.
  • Page 13: Section 6 - Maintenance

    Section 6 – MAINTENANCE The repair and maintenance of the Model 5306 includes replacement of the T3-style lamp and quartz window and cleaning of the reflector. LAMP REMOVAL/REPLACEMENT/INSTALLATION: The T3-style lamp is installed into the Model 5306 heater when shipped from the factory. The following procedure details the process to replace the lamps in the Model 5306 (reference Figure 6- 1, 6-2, &...
  • Page 14 3. If installed in the heater, remove the quartz window from the heater by removing the screws on the window brackets, and carefully set the window aside (see Figure 6-2). Take this opportunity to clean the window using non-abrasive cleaning solvent and clean, soft cotton cloth (see Section 6-2). Figure 6-2.
  • Page 15 Figure 6-3. Model 5306 Lamp Removal. 5. While holding the lamp, gently pull the lead wires out of the ceramic terminal blocks, out of the lamp clips, and set the old lamp aside for disposal. (The model 5306-02 does not have lamp clips, but a half-circle groove that the lamp fits in.) 6.
  • Page 16: Quartz Window Cleaning And Replacement

    Quartz Window Cleaning and Replacement: The optional quartz window can be replaced or removed from the Model 5306 for periodic cleaning. Use the following procedure to remove/reinstall/clean the quartz window: 1. Remove the quartz window from the heater by removing the screws on the window brackets, and carefully set the window aside .
  • Page 17: Section 7 - Spare & Replacement Parts

    Section 7 – SPARE & REPLACEMENT PARTS Figures 7-1. Model 5306 Parts Identification. ITEM PART NO. DESCRIPTION 5306-02 5306-05 5306-10 5306-16 5306-25 5306-38 054979-001 Panhead Screw, 2-56X3/16 054979-026 Panhead Screw, 4-40X3/4 054979-099 Panhead Screw, 8-32X5/8 054979-123 Panhead Screw, 10-32X.5 063042-001 Plug, 1/2NPT X 1/4LG 100571-001 Terminal Block, 10A...

Table of Contents