Sharp LC-26D4U Service Manual page 29

Lcd color television
Hide thumbs Also See for LC-26D4U:
Table of Contents

Advertisement

Start measurement
Repeat until RGB
become the target
values.
Completion of adjustment
2-7. Initialization to factory settings
After the shipping setting, pull off the AC cord.
Note: Never turn on the power after the shipping setting. If power is turned on, perform the shipping setting
again.
Adjustment item
1
Initialization
C
Adjust RB to the target xy values.
MG1RXXXX
MG1BXXXX
* XXXX indicates the adjusted values between 0000 and 1023
(4 digit decimal number with zero fill).
* G is fixed.
* The default adjustment value of RGB is the parameter value of
the LEV1 command multiplied by 2.
Writing of adjusted values
MSET0003
Deleting adjustment patterns
MSET0000
Adjustment conditions
Place the cursor on the [INDUSTRY INIT] row, set "ON" with [+] or [-] of
It turns off with AC pow-
the [VOL] key, and press the [ENT] key.
er supply.
Version confirmation screen appears.
[SUCCESS] on a green line indicates that the setting is successfully
completed.
(In case of an error, [ERROR] and an error code appear on a red line.)
Turn off the AC power.
1. User setting
2. Channel data (e.g. broadcast frequencies)
3. Password data
4. Operation time
5. Maker's optional setting
6. Auto installation flag
7. V-CHIP block setting
Set
The adjustment value is
reflected in the image.
Adjustment values are set.
OK
Writing is complete.
OK
Deletion is complete.
OK
Adjustment procedure
29
LC-26D4U
LC-32D4U
LC-37D4U

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-32d4uLc-37d4u

Table of Contents