4. INSTALLATION

4.1 Checking of placement
Hose extension
If extended external part is necessary when connecting the drain hose, the length of the drain hose should be
less than 3 m and the height should be below 10 cm.
Install the machine 10 cm or more away from the wall.
Water supply hose
Drain hose
Below 10 cm
3 m max.
- 8 -
NA-F60A6, F70A6, F756A, F70G6, F70G6P, F70X6, F806X
Connect the water supply hose to the
water supply valve screw.
Elbow
Nut
1. Push the water supply hose nut straights
onto the water supply valve screw.
2. Hold the elbow bny lifting it up, screw the
nut onto the water supply valve screw,
and firmly tighten the nut.
3. After the nut is tightened, check whether
or not the elbow is unsteady or loose.
4. After tightening, open the faucet to confirm
that there is no water leakage.
[ Cautions ]
Firmly tighten the nut, otherwise water
leakage will result.
Water Pressure Rating :
4
2.9 x 10
~ 9.8 x 10 Pa
Do not put hose tip
under the water
Good Example
Water supply
valve screw
5
Over 10 cm

Hide quick links: