KX-T7730X
7 CIRCUIT OPERATIONS
7.1.
KEY INPUT CONTROL CIRCUIT
Sequential input information is executed by dynamic scanning.
The ports R20~R23, R30, R31 of IC1 are brought to high status consecutively.
If a key is pressed, the key-in information input is executed by ports R00~R03, R10~R13.
11