Inter-m IMN-511 Operation Manual

High resolution ip camera inter-m imn-511/ imn-512

Advertisement

Quick Links

Operation
Manual
IMN-511/512
High Resolution IP Camera
* Before starting use of this product, be sure to check the broadcasting
mechanism and the power voltage.

Advertisement

Table of Contents
loading

Summary of Contents for Inter-m IMN-511

  • Page 1 Operation Manual IMN-511/512 High Resolution IP Camera * Before starting use of this product, be sure to check the broadcasting mechanism and the power voltage.
  • Page 2: Features

    Never place the unit near radiators, in front of heating vents, in excessively humid or dusty location to avoid early damage and for your years of quality use. Connect your complementary components as illustrated in the following page. IMN-511/512 O/P Manual Auto Iris Plug S/W & Manual CD...
  • Page 3: Table Of Contents

    3. Connecting a Monitor ..........22 4. Connection method for MIC and Speaker....24 5. Connecting a network..........24 6. Connecting Sensor In/Out ..........25 7. Connecting PAN/TILT ..........26 Setting IP Address ............27 Camera Setup ..............32 Specifications ..............35 Trouble Shooting ............37 IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 4 IMN-511/512(series) is 540 High Resolution DAY & NIGHT Network Camera adopting SONY CCD with 410,000 pixels of high picture quality, which is a color camera realizing 0.01Lux with lowest light intensity. It supports high quality MPEG-4, connected with Ethernet or xDSL/Cable modem at the speed of 30 frames/sec.
  • Page 5 - Streamer Based motion detection - 20*15 cell - 0 ~ 100 Sensitivity Resolution Networking - ARP, ICMP, TCP/IP, UDP/IP, RTP/RTSP, HTTP server, FTP Server, SMTP client, TIME client, FTP client, DHCP client - 10/100 Base-T Fast Ethernet (Auto Negotiation) IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 6 - Speaker output Connections & Connectors - 485 Transceiver - 1 Sensor Input (normal open/normal close selectable) - 1 Relay Output Power - Power Source - 12VDC Adapter - Power consumption 7.2Watt@12VDC for IMN-511 8.4Watt@12VDC for IMN-512 IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 7 Attentions: Pour prévenir les chocs électriques ne pas utiliser cette fiche polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 8 DO NOT GRASP OR PULL THE POWER DO NOT DISSEMBLE THE PRODUCT OR CORD OR PLUG WITH WET HANDS. INSERT UNDESIRED FOREIGN SUBSTANCES. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 9: Connecting The Camera

    To sweep the camera, use a dry and soft cloth. DO NOT INSTALL THE CAMERA CLOSELY AT DO USE A DRY CLOTH TO CLEAN THE THE MAGNETIC CAMERA * Please check that the power satisfies the normal specification before connecting the camera. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 10 IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 11 If user want to change the position, please use same screw to fix it from other position. It may cause unexpected defectiveness once you use other type of screw. * No supplying of Supporter(Bracket, Triangle bar, Housing) IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 12 IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 13 Connects to Ethernet(10/100Base-T) and xDSL/Cable modem network with RJ-45 Connector. *Supportable network type : LAN(10/100 Base-T) POWER INPUT TERMINAL Supplies the power to IMN-511/512 with a DC 12V input terminal. External Power : DC Power Adaptor(12V) Power Consumption : 7.2Watt@12V DC for IMN-511 8.4Watt@12V DC for IMN-512...
  • Page 14 It is a volume to adjust the brightness of DC iris lens. Turning this volume to the left makes it darker, and to the right, brighter. FACTORY RESET BUTTON IMN-511/512 parameters restored factory default values. * Default IP Address : 192.168.1.100 Subnet Mask : 255.255.255.0 Gate way : 192.168.1.1 VIDEO OUTPUT PORT It is a video output port, which is set to 75Ω...
  • Page 15: Lens Mounting And Connection

    This section is intended for use by the product administrator. Operators and viewers should check the detail through enclosed CD and manual file. You may connect the following items with IMN-511/512, such as lens mounting, connecting a monitor, network devices, audio device, alarm sensors, Serial (PAN/TILT) controllers.
  • Page 16 CONNECTION METHOD FOR C MOUNT LENS AND CS MOUNT LENS 1. CAMERA ADAPTOR 2. C MOUNT ADAPTOR 3. CS MOUNT ADAPTOR 4. STOP SCREW Upon mounting a CS mount lens, assemble Upon mounting a C mount lens, assemble IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 17 C lens by turning it clockwise as shown in Figure3. WHEN USING AN AUTO IRIS LENS 1) Peel off about 8mm of a lens cable’s covering from the end. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 18 The lens includes a circuit that controls an iris. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 19 5) If you use a DC iris lens, select DC from the lens selection switch; if a video iris lens, select VIDEO. IMN-511/512 * Recommend Auto Iris Lens in the condition of bad lighting condition.(The place where lighting is continuously changing) IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 20: Lens Adjustment

    IN CASE OF DC IRIS LENS Turn off the AGC switch on the back of the mainframe. Adjust the VR in rear panel of IMN-511/512 to control Iris. Select the AGC switch ON or OFF. To make the monitor screen Turn the level...
  • Page 21 This system is included in the lens itself and receives the power and video output from the camera. In some system, a turbo system is included inside a camera, and it is connected to a lens via 4 lines. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 22 Adjust more than 2 times repeatedly, between to adjust correctly. Set the lens zoom as maximum telephoto direction, being careful not to focus out, holding flange back fixing screw and fix flange back adjustment ring. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 23 At a wide-angle mode, you cannot identify the slight error in focus. But in at a telephoto mode, you can identify the difference clearly as you zoom in. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 24: Connecting A Monitor

    * In case of using a video cable, connect a monitor and the video output port of a camera with a BNC cable. Cable Length(Max) 3C - 2V 200m 5C - 2V 350m 7C - 2V 500m IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 25 Intermediate Video Device Final Video Device IMN-511/512 IMN-511/512 produces the corresponding video signal, If connected with external device to Video Out(loop through BNC). The terminal resistance of 75Ω will be automatically seized by the connection with external device. * Caution : External surveillance control or monitoring unit...
  • Page 26: Connection Method For Mic And Speaker

    CONNECTION METHOD FOR MIC and SPEAKER (AUDIO Product) SPEAKER *CAUTION : Connects to Speaker include AMP or lead to AMP CONNECTING A NETWORK HUB or Cable modem IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 27: Connecting Sensor In/Out

    Alarm 1 Sensor Alarm Alarm sensors and external devices are usable by connecting to Sensor and Relay terminals of the rear of the IMN-511/512 respectively. *CAUTION : When connecting an external device to Relay terminal, you are recommended to use additional “Relay”...
  • Page 28: Connecting Pan/Tilt

    Refer to the PAN/TILT controller manual and confirm & reset the following items. • Baud Rate • Data Bit • Stop Bit • Parity Bit • Controller ID (be careful not to duplicate a different controller *There must be connected only one PAN/TILT controller. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 29 ) on the Start menu. 2. Select “IP Change” Menu of Mouse Right button Search device by click the ‘Scan’ button. 3. Setting the product’s IP address, Subnet mask, Gateway and Host name to apply, click the ‘OK’. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 30 You can check the detail Web-configuration through enclosed CD and manual file. 6. In ‘Network Setup’, you must enter the subnet mask and gateway address to correct to your network environment. * Please confirm that the all network setting is set correctly. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 31 PC that is in the local network with the IMN- 511/512. 2. The ‘ScanDevice’ program have an effect in 10 minutes after booting the IMN-511/512. So if 10 or more minutes pass after booting without setting a new IP address, you must reboot it to set a new IP address.
  • Page 32 IMN-511/512 use the dynamic IP address assigned from DHCP Server, check here. (In case of using the cable modem) - Manual Setting : When the IMN-511/512 use a static IP address, check here. Enter the desired network configura- tions of the IMN-511/512 manually. The IP address that was already set by the Remote IP Set program will show.
  • Page 33 Internet Gateway. 4. If a firewall is installed, the network port used by IMN-511/512 must be opened to permit the remote connection via external network. Please ask to your network administrator all about it.
  • Page 34 IMN-511/512. FLICKERLESS Enables or disables FLICKERLESS function of the IMN- 511/512. Enables or disables AGC(AUTOMATIC GAIN CONTROL) function of the IMN-511/512. DAY & NIGHT Enables or Fix DAY & NIGHT function of the IMN-511/512. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 35 * If AGC is OFF, Day&Night function is always fixed color mode. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 36 In regardless of illumination, current mode (B/W or COLOR mode) is fixed. * In case of ON/OFF of power source, FIX is always color mode. * If AGC is OFF, Day&Night function is always fixed color mode. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 37 Compression PCM / ADPCM RECORD(Network) Protocol Schedule TIME TABLE (Schedule, Motion-detected, Sensor-triggered) MOTION DETECTION Method Hardware-based Detection Area 20x15 Cell Area TELEMETRY Sensor Input 1 Input Sensor Output 1 Output(TTL) Serial Port RS-485 (Transceiver for PAN/TILT/ZOOM) IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 38: Specifications

    Web Browser Viewer, Setup (video, audio, network, time & date, event, recording, etc.) Application SDK support for developing applications(viewer, search, etc.) Bundle applications: viewer, search, etc. Specifications and design subject to change without notice for improvements. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 39 It may show white blemish in the condition of darkness. This dot appeared in use by external factors. * White blemish Cosmic rays or alpha rays affected to the CCD pixel and make white dot from the CCD surface in the condition of dark. IMN-511/512(HIGH RESOLUTION IP CAMERA)
  • Page 40 MADE IN KOREA www.inter-m.com November 2008 122887...