Opeartion :
z
z
b: Baud rate selection
0= 19,200 bps 1= 9,600 bps
m: Test Mode selection
0= Self loop test
ZZ: Time out number (seconds) input between data
(default is 3 seconds. Input ZZ, ZZ seconds will be the time of time out.)
X: 0= Normally select 0.
1= When error is happened, print error receipt before retry operation.
Test procedure
1) Operate the send machine first. The send machine will wait the "C" signal (send
request) reception from the reception machine.
The send machine will wait the send request signal about 30 seconds. When it is over
30 seconds, the time out error will be printed on the receipt.
2) Operate the reception machine. Then, the both machines are communicated each
others. This time first block data wait time is 5 seconds. The total resend request time
is 5 time.
3) During communication waiting time, the display will show the "-" brinking on the most
left side digit of segment display. When the data is OK, the reception/transmission
packet number will be displayed on the segment display.
NOTE1: To stop this opeartion, press any or trun off the mode key switch.
NOTE2: The send packet data format is as follows:
( Communication format is 8 bits, even parity, stop bit= 1bit fixed.)
Block counter
STX
2 bytes
03h
Total 1,024 bytes
[PRINT]
Normal End
Error End (Time out error)
b
m
7
2
X
7
2= 4,800bps
1= Reception mode
Data (55h X 1,020 pcs.)
E : Error status
(01 : Framing error)
(02 : Over run error)
(04 : Parity error)
(40: Transmit/ Receive data error/ Data is not 55.)
(80 : Time out error)
- 46 -
#2
Key
3= 2,400bps
2= Send mode
[DISPLAY]
Dot display
Segment display
4= 38,400 bps
LRC
Count data block

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents