Heatsink sensor error/Heatsink over heat
Indoor display
⊙
Outdoor display
⊙
⊙
1.Checklist :
1) Are there screws assembly in PBA-heatsink?
2) Is the gap PBA-heatsink
3) Is the fan operation normal?
4) Is the cover assembly in conrol-box normal?
2. Troubleshooting procedure
Restart after power off.
Are there screws in PBA-heatsink?
(4 screws)
YES
Is the fan operation normal?
YES
Exchange the Outdoor PBA
12-20
○
⊙
Outdoor error
⊙
●
Heatsink sensor error
●
⊙
Heatsink over heat error
NO
NO
Fastening the screw
Check the fan connection
Change the Fan motor