Loop Of The Station Detect Error - Haier HSU-09RS03/R2(SDB) Service Manual

Wall mounted type dc inverter s -series
Hide thumbs Also See for HSU-09RS03/R2(SDB):
Table of Contents

Advertisement

7.4.11 Loop of the station detect error

Outdoor Display
LED1 flash 18 times
LED1 flash 19 times
Method of
the position of the compressor rotor can not detected normally
Malfunction
Detection
Malfunction
when the The wiring of compressor is wrong or the connection is poor;
Decision
or the compressor is damaged
Conditions
Supposed
Causes
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector, or parts
Within 3 minutes after the machine
is supplied with power and turned
on with the remote controller, the
compressor could not start up
At frist, the compressor start up ,soon
the compressor stopped with the LED1
on the outdoor PCB blinks 1Hz for 19
times
HSU-09/12RS03/R2(SDB)
Faulty The wiring of compressor
Faulty compressor
Faulty PCB
damage may be occurred.
NO
Indoor Display
F11
Indoor Display
F28
YES
YES
IPM Module is damaged and
needs replacing.
the Malfunctions exist also, .
The compressor is damaged
replace a new one
64
Service Diagnosis
1. The wiring of compressor is
incorrect or the connection is
poor;
2. The compressor is damaged
Malfunction unso
Domestic air conditioner

Hide quick links: