2. HALL Adjustment

For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Measurement Point
DDS display data of EVF or TV monitor
(Note 3)
Measuring Instrument
Adjustment Page
F
Adjustment Address
2F, 30
Specified Value
96 to 9A during IRIS OPEN (Note 1)
1C to 20 during IRIS CLOSE (Note 2)
Note 1: Select page: 2, address: 01, set data: 01, and press the
PAUSE button of the adjusting remote commander.
Note 2: Select page: 2, address: 01, set data: 03, and press the
PAUSE button of the adjusting remote commander.
Note 3: DDS display data of EVF or TV monitor.
00 00XX
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 03.
3) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 01, set data: 03, and press the PAUSE
button.
5) Select page: F, address: 30, set data: 80, and press the PAUSE
button.
6) Select page: F, address: 2F, set data: 40, and press the PAUSE
button.
7) Read the DDS display data (the bottom two digits of the display
data at the bottom right of the EVF display or the TV monitor),
and this data is named K
.
2
8) Select page: F, address: 2F, set data: 30, and press the PAUSE
button.
9) Read the DDS display data, and this data is named K
10) Select page: 2, address: 01, set data: 01, and press the PAUSE
button.
11) Read the DDS display data, and this data is named W
12) Select page: F, address: 2F, set data: 40, and press the PAUSE
button.
13) Read the DDS display data, and this data is named W
14) Convert W
, W
, K
, K
, to decimal notation, and obtain W
1
2
1
2
W
' , K
' , K
'. (Refer to Table 5-1-2. "Hexadecimal notation -
2
1
2
decimal notation conversion table".)
15) Calculate X
' using the following equations (decimal notation
1
calculation).
A'= W
'+ K
'– W
'– K
'
2
1
1
2
B'= W
' – K
'
1
1
X
'=[1952+(48 x A')–(16 x B')] / A'
1
16) Convert X
' to hexadecimal notation, and obtain X
1
(Round off to one decimal place)
17) Select page: F, address: 2F, set data: X
button.
18) Select page: 2, address: 01, and set data: 01, and press the PAUSE
button.
19) Select page: F, address: 30, change the data and adjust the DDS
display data to "98".
20) Press the PAUSE button of the adjusting remote commander.
21) Select page: 2, address: 01, and set data: 03, and press the PAUSE
button.
n Object data
.
1
.
1
.
2
Equation 1
Equation 2
Equation 3
.
1
, and press the PAUSE
1
22)Read the DDS display data, and this data is named K
within the "1C" to "20" range, perform "Processing after
completing adjustments". If it is lies outside the range, perform
the following adjustments.
23)Convert K
to decimal notation, and obtain K
0
24)Calculate X
' using the following equations (decimal notation
2
calculation).
C'= 152 – B'– K
X
'=[(122 – B') x ( X
2
( X
' and B' are values obtained from equations 2) and 3) )
1
25)Convert X
' to hexadecimal notation, and obtain X
2
(Round off to one decimal place)
26)Select page: F, address: 2F, set data: X
button.
27)Select page: 2, address: 01, set data: 03, and press the PAUSE
button.
28)Select page: F, address: 30, change the data and adjust the DDS
display data to "1E".
29)Press the PAUSE button of the adjusting remote commander.
30)Select page: 2, address: 01, set data: 01, and press the PAUSE
button.
' ,
31)Check the DDS display data lies within the "96" to "9A" range.
1
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button.
4) Select page: 0, address: 03, and set data: 00.
5-14
'.
0
'
Equation 4
0
' – 48)+(48 x C')] / C'
1
Equation 5
.
2
, and press the PAUSE
2
. If K
lies
0
0

Advertisement

Table of Contents
loading

Table of Contents