EEDEN07-721 technical data ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300...
Page 2
Altherma ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300 Daikin’s unique position as a man- “The present publication is drawn up by way of information only and ISO14001 assures an effective environmental ufacturer of air conditioning equip- does not constitute an offer binding upon Daikin Europe N.V.. Daikin...
Page 3
EEDEN07-721 technical data ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300...
A l t E R H R - 4 • Cost effective alternative to a fossil fuel boiler • Easy to install • Low energy bills and low CO2 emissions • Total solution for year round comfort • Altherma • Outdoor units...
0.98 0.98 0.98 0.98 0.98 0.98 Area Nr of Stages Tube type Hi-XSS(8) Type WF fin Treatment Anti-corrosion treatment (PE) Type Propeller Quantity Air Flow Rate Heating High m³/min (nominal at Cooling High m³/min 230V) • Altherma • Outdoor units...
Page 8
Pressure Cooling Sound Power Sound Pressure Sound Level Heating Sound (Night quiet) Pressure Cooling Sound Pressure Refrigerant Type R-410A Charge Control Expansion valve (electronic type) Nr of Circuits Refrigerant Oil Type Daphne FVC68D Charged Volume • Altherma • Outdoor units...
27.4 31.9 running Current Recomended fuses Wiring For Power Remark See installation manual outdoor unit 4PW37976-1B connections Supply For connection Remark See installation manual outdoor unit 4PW37976-1B with indoor Power Supply Intake Outdoor unit only • Altherma • Outdoor units...
Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range D1= 3-8°C 3. Power input Power input is total input of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/003-2006 Pump power input to be added=90W (according EN14511) 3TW57752-1 • Altherma • Outdoor units...
Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range D1= 3-8°C 3. Power input Power input is total input of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/003-2006 Pump power input to be added=90W (according EN14511) 3TW57752-1 • Altherma • Outdoor units...
Liquid pipe connection ∅9.5 flare Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake (knock out hole ∅34) control wiring intake (knock out hole ∅27) Drain outlet 3TW57764-1 • Altherma • Outdoor units...
• Outdoor units • R-410A • ERHQ Wiring diagram 6 - 1 External connection diagram ELECTRICAL CONNECTION DIAGRAM ALTHERMA (011/014/016 CLASS) Standard parts Power supply Applicable for the following models: OUTDOOR UNIT OUTDOOR UNIT: ERHQ011/014/016AAV3 3 core unit power supply: 230V + earth...
= A-Weighted sound pressure level. (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa. If sound is measured under actual installation conditions, the measured value Measuring location will be higher due to environmental noise and sound reflections. (Discharge side) • Altherma • Outdoor units...
Page 16
= A-Weighted sound pressure level. (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa. If sound is measured under actual installation conditions, the measured value Measuring location will be higher due to environmental noise and sound reflections. (Discharge side) • Altherma • Outdoor units...
A l t E K H R - 4 • Cost effective alternative to a fossil fuel boiler • Easy to install • Low energy bills and low CO2 emissions • Total solution for year round comfort • Altherma • Indoor units...
Select diameter and type according to national and local heater regulations Electric heater Type Power Supply Phase Frequency Hz Voltage Current Running 15.1 15.1 15.1 Current Voltage range Minimum -10% -10% -10% Maximum +10% +10% +10% • Altherma • Indoor units...
Page 21
Select diameter and type according to national and local heater regulations Electric heater Type Power Supply Phase Frequency Hz Voltage Current Running 22.6 22.6 22.6 Current Voltage range Minimum -10% -10% -10% Maximum +10% +10% +10% • Altherma • Indoor units...
Page 22
3V3 model which has only 1 capacity step. For 6W1 and 9W1 models, neutral line only required for optional booster heater power supply. Model without optional back up heater is powered via outdoor unit. • Altherma • Indoor units...
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow Wire colour Field wiring BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW57556-4 7 For EKSWWU*V3, refer to option manual • Altherma • Indoor units...
Page 28
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow Field wiring Wire colour BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW57556-5 7 For EKSWWU*V3, refer to option manual • Altherma • Indoor units...
Page 29
This wiring diagram only applies to the indoor unit. Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option. Do not operate the unit by short-circuiting any protection device. For EKSWWU*V3, refer to option manual. • Altherma • Indoor units...
Page 30
This wiring diagram only applies to the indoor unit. Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option. Do not operate the unit by short-circuiting any protection device. For EKSWWU*V3, refer to option manual. • Altherma • Indoor units...
Page 31
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow Field wiring Wire colour BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW57556-2 7 For EKSWWU*V3, refer to option manual • Altherma • Indoor units...
Page 32
This wiring diagram only applies to the indoor unit. Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option. Do not operate the unit by short-circuiting any protection device. For EKSWWU*V3, refer to option manual. • Altherma • Indoor units...
Page 33
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow See note 7 Field wiring For EKSWWU*V3 Option BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW56716-3C 7 For EKSWWU*V3, refer to option manual • Altherma • Indoor units...
Page 34
This wiring diagram only applies to the indoor unit. Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option. Do not operate the unit by short-circuiting any protection device. For EKSWWU*V3, refer to option manual. • Altherma • Indoor units...
Signal Indoor unit Thermistor cable Note: min. distance to power cable = 3cm User interface 3TW56719-6A ELECTRICAL CONNECTION DIAGRAM ALTHERMA (011/014/016 CLASS) Standard parts Power supply Applicable for the following models: OUTDOOR UNIT OUTDOOR UNIT: ERHQ011/014/016AAV3 3 core unit power supply: 230V + earth...
If leaving water temperature is below 12°C, condensation on water piping will happen. Dry bulb temperature [°C] 1. Refer to psychometric chart for more information. 2. If condensation is expected, installation of EKHBDP - drainpan kit must be considered. 4TW57759-3 • Altherma • Indoor units...
: Units with optional back up heater Leaving condenser water temperature (°C) Outdoor temp. (°CDB) : Booster heater operation only : Units with optional back up heater or booster heater operation only Water temperature sanitary tank (°C) 4TW57553-1A • Altherma • Indoor units...
Page 38
• Indoor units • R-410A • EKHBH Operation range ERHQ - EKHBH(X)016 COOLING MODE HEATING MODE outdoor temp (°CDB) outdoor temp (°CDB) leaving condensor leaving evaporator water temperature (°C) water temperature (°C) NO HEAT PUMP OPERATION BACK UP HEATER ONLY 4TW57753-1A • Altherma • Indoor units...
ESP: External static pressure Flow: waterflow trough the unit Warning: Selecting a flow outside the curves can cause damage to or malfunction of the unit. See also minimum and maximum allowed water flowrate in the technical specifications. 4TW56749-2 • Altherma • Indoor units...
Page 40
See also minimum and maximum allowed ESP: external static pressure water flowrange in the technical specifications. Flow: waterflow through the unit 2. Water quality must be according to EN directive EC 98/83 EC. 4TW57759-1 • Altherma • Indoor units...
A l t E K H R - 4 • Cost effective alternative to a fossil fuel boiler • Easy to install • Low energy bills and low CO2 emissions • Total solution for year round comfort • Altherma • Indoor units...
Manometer Drain valve / Fill valve Shut off valve Air purge valve Total water volume (6) Refrigerant Gas side diameter 15,9 Circuit Liquid side diameter 6,35 6,35 6,35 9,52 9,52 9,52 Sound Level Sound Pressure • Altherma • Indoor units...
Current Running Current Voltage range Minimum -10% -10% Maximum +10% +10% +10% Wiring For power Quantity of wires connections supply backup Type of wires Select diameter and type according to national and local heater regulations • Altherma • Indoor units...
Page 45
Type of wires Select diameter and type according to national and local heater regulations Electric heater Type Power Supply Phase Frequency Voltage Current Running 22.6 22.6 22.6 Current Voltage range Minimum -10% -10% Maximum +10% +10% +10% • Altherma • Indoor units...
Page 46
3V3 model which has only 1 capacity step. For 6W1 and 9W1 models, neutral line only required for optional booster heater power supply. Model without optional back up heater is powered via outdoor unit. • Altherma • Indoor units...
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow Wire colour Field wiring BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW57556-4 7 For EKSWWU*V3, refer to option manual • Altherma • Indoor units...
Page 52
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow Field wiring Wire colour BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW57556-5 7 For EKSWWU*V3, refer to option manual • Altherma • Indoor units...
Page 53
This wiring diagram only applies to the indoor unit. Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option. Do not operate the unit by short-circuiting any protection device. For EKSWWU*V3, refer to option manual. • Altherma • Indoor units...
Page 54
This wiring diagram only applies to the indoor unit. Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option. Do not operate the unit by short-circuiting any protection device. For EKSWWU*V3, refer to option manual. • Altherma • Indoor units...
Page 55
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow Field wiring Wire colour BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW57556-2 7 For EKSWWU*V3, refer to option manual • Altherma • Indoor units...
Page 56
This wiring diagram only applies to the indoor unit. Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option. Do not operate the unit by short-circuiting any protection device. For EKSWWU*V3, refer to option manual. • Altherma • Indoor units...
Page 57
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow See note 7 Field wiring For EKSWWU*V3 Option BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 3TW56716-3C 7 For EKSWWU*V3, refer to option manual • Altherma • Indoor units...
Page 58
This wiring diagram only applies to the indoor unit. Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option. Do not operate the unit by short-circuiting any protection device. For EKSWWU*V3, refer to option manual. • Altherma • Indoor units...
Signal Indoor unit Thermistor cable Note: min. distance to power cable = 3cm User interface 3TW56719-6A ELECTRICAL CONNECTION DIAGRAM ALTHERMA (011/014/016 CLASS) Standard parts Power supply Applicable for the following models: OUTDOOR UNIT OUTDOOR UNIT: ERHQ011/014/016AAV3 3 core unit power supply: 230V + earth...
If leaving water temperature is below 12°C, condensation on water piping will happen. Dry bulb temperature [°C] 1. Refer to psychometric chart for more information. 2. If condensation is expected, installation of EKHBDP - drainpan kit must be considered. 4TW57759-3 • Altherma • Indoor units...
: Units with optional back up heater Leaving condenser water temperature (°C) Outdoor temp. (°CDB) : Booster heater operation only : Units with optional back up heater or booster heater operation only Water temperature sanitary tank (°C) 4TW57553-1A • Altherma • Indoor units...
Page 62
• Indoor units • R-410A • EKHBX Operation range ERHQ - EKHBH(X)016 COOLING MODE HEATING MODE outdoor temp (°CDB) outdoor temp (°CDB) leaving condensor leaving evaporator water temperature (°C) water temperature (°C) NO HEAT PUMP OPERATION BACK UP HEATER ONLY 4TW57753-1A • Altherma • Indoor units...
ESP: External static pressure Flow: waterflow trough the unit Warning: Selecting a flow outside the curves can cause damage to or malfunction of the unit. See also minimum and maximum allowed water flowrate in the technical specifications. 4TW56749-2 • Altherma • Indoor units...
Page 64
See also minimum and maximum allowed ESP: external static pressure water flowrange in the technical specifications. Flow: waterflow through the unit 2. Water quality must be according to EN directive EC 98/83 EC. 4TW57759-1 • Altherma • Indoor units...
Page 65
........71 • Altherma • Sanitary Hot Water...
E K S R - 4 • Cost effective alternative to a fossil fuel boiler • Easy to install • Low energy bills and low CO2 emissions • Total solution for year round comfort • Altherma • Sanitary Hot Water...
3/4’’ FBSP Hot water out Diameter inch 3/4’’ FBSP 2-2 ELECTRICAL SPECIFICATIONS EKSWW150V3 EKSWW200V3 EKSWW300V3 EKSWW200Z2 EKSWW300Z2 EKSWWU150V3 EKSWWU200V3 EKSWWU300V3 Unit Power Supply Phase Frequency Hz Voltage Nominal running current Fuse Size Phase • Altherma • Sanitary Hot Water...
(3) Efficiency of sanitary hot water production: In the ALTHERMA by Daikin system both the heat-pump and the electric booster heater supply the energy to produce sanitary hot water. The higher the portion of energy supplied by the heat-pump, the more energy efficient the system is.
Water mains out female 3/4’’ BSP Thermistor connection female 1/2’’ BSP Flow (from hydrobox) female 3/4’’ BSP Return (to hydrobox) female 3/4’’ BSP Switchbox Clixon Connection female 3/4’’ BSP Power entrance Required service space around the tank 3TW56714-4A • Altherma • Sanitary Hot Water...
• Sanitary Hot Water • R-410A • EKSWW Wiring diagram 6 - 1 External connection diagram ELECTRICAL CONNECTION DIAGRAM ALTHERMA (011/014/016 CLASS) Standard parts Power supply Applicable for the following models: OUTDOOR UNIT OUTDOOR UNIT: ERHQ011/014/016AAV3 3 core unit power supply: 230V + earth...