8. Cooling and fan operation

PLM+ devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power
levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or
lids are placed at the front or rear of the rack. Never attempt to reverse the airflow. Make sure an adequate
air supply is provided in front of the PLM+ device, and that the rear of the device has sufficient space to allow
air to escape. It is recommended to keep the ambient temperature around the device as cool as possible. An
increased temperature can have a significant negative impact on the expected lifetime on the components
inside the PLM+ Series device.
Note: Fit solid blanks (not ventilation blanks) to unused rack spaces to ensure effective air circulation.
Leaving gaps in between items of equipment degrades the effectiveness of forced-air cooling.
If installing one or more PLM+ devices in a rack with other fan-cooled equipment, confirm that all other
equipment also uses front-to-rear airflow for cooling. If this precaution is not observed, there is a risk of
overheating, as units with the reverse airflow will be drawing in air which has already been heated by the
PLM+ Series devices.
The PLM+ device is equipped with a sophisticated temperature sensing system which protects it from any
overheating which may occur as a result of inadequate ventilation.

9. Operating voltage

PLM+ Series has a universal power supply and its mains nominal and operating voltages are specified in the
Technical Specifications (see section 15). PLM+ Series can be ordered with a variety of mains plugs. If the mains
plug (AC plug) fitted to the mains cable (AC cord) is not appropriate for your country it can be removed and a
locally-sourced one fitted instead. If you are not 100% confident of your competence to replace the mains plug (AC
plug), the task should be carried out by qualified personnel.
Note: In-rush current is controlled and limited during the soft-start sequence. This enables multiple
PLM+ Series Devices on the same AC mains circuit to be turned on simultaneously.