INSTALLATION INSTRUCTIONS - DUAL FUEL
CONNECT TO THE ELECTRICITY SUP-
PLY
Warning: This appliance must be earthed.
The appliance must be installed by a
competent electrician using a double
pole control unit of 32 ampere minimum
capacity with 3mm minimum contact
separation at all poles.
We recommend that the appliance is con-
nected by a qualified electrician who is a
member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regula-
tion.
1. Access to the mains terminal is gained
by opening the terminal block cover at
the rear of the appliance (use a small flat-
bladed screwdriver).
2. Connection should be made with
6.0mm2 flexible twin and earth cable.
3. First strip the wires, then push the
cable through the cable clamp in the
terminal block cover.
4. Connect the cable to the terminal block
and tighten the cable clamp screw (see
diagram).
5. Close the terminal box, ensuring that
the cover is engaged on the locking tabs.
Your appliance will be fitted with one of the
two terminal blocks below, Block A, Block B