S E R V I C E

Technical data

Electrical connection
Rated voltage
Main connection
Power usable contemporaneously
Lower heating element
Forced air
Dual grill left
Dual grill total
Electrical components
Auto timer
Accessories
Pan set enameled
Grid chrome
Failure codes
Fault
F01
Open or short circuit
of the temperature probe
F02
Overheating of the oven
F03
Capricorn not properly configured
F04
WISP protocol doesn't work
(communication error)
Whirlpool Europe
Customer Service
230-240 V ~
230-240 V
2400
1450
1920
1440
2350
Interface module
415 x 318
446.5 x 340
Defect
Replace the temperature probe
Replace Capricorn
(oven power unit)
Replace Capricorn
(oven power unit)
Replace Capricorn (oven power unit)
or replace Scales (hob control unit)
6AKZ 186/IX
8585 186 53010
1N~ 50
Hz
W
W
W
W
W
mm
mm
Intervention
Service sticker
18.04.2000 / Page 5
Doc. No: 4812 725 12877